Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
183
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0050 # 08 Y:1985 | 08 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,212 | $800 | Implemented |
CO0050 # 05 Y:1985 | 05 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,313 | $1,600 | Implemented |
CO0050 # 03 Y:1985 | 03 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $888 | $200 | Implemented |
CO0050 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $16,221 | $2,791 | Implemented |
CO0050 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $159 | $200 | Implemented |
CO0050 # 06 Y:1985 | 06 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $6,022 | $1,570 | Implemented |
CO0049 # 09 Y:1985 | 09 | 1985 | IMPROVE LUBRICATION PRACTICES | $379 | $100 | Implemented |
CO0049 # 04 Y:1985 | 04 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,411 | $4,000 | Implemented |
CO0049 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $296 | $250 | Implemented |
CO0044 # 09 Y:1985 | 09 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $6,495 | $122 | Implemented |
CO0044 # 03 Y:1985 | 03 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,668 | $100 | Implemented |
CO0045 # 05 Y:1985 | 05 | 1985 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $440 | $300 | Implemented |
CO0048 # 05 Y:1985 | 05 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $128 | $300 | Implemented |
CO0049 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,488 | $300 | Implemented |
CO0047 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $414 | $1,200 | Implemented |
CO0049 # 05 Y:1985 | 05 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,347 | $200 | Implemented |
CO0048 # 03 Y:1985 | 03 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,843 | $25 | Implemented |
CO0049 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $614 | $1,050 | Implemented |
CO0045 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,736 | $300 | Implemented |
CO0048 # 09 Y:1985 | 09 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $29,091 | $2,343 | Implemented |
CO0048 # 02 Y:1985 | 02 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,297 | $400 | Implemented |
CO0048 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $541 | $750 | Implemented |
CO0048 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $11,078 | $47 | Implemented |
CO0049 # 07 Y:1985 | 07 | 1985 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,828 | $2,800 | Implemented |
CO0049 # 08 Y:1985 | 08 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,647 | $20,000 | Implemented |