IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,456

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0052 # 04 Y:1986 04 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $852 $300 Implemented
CO0052 # 05 Y:1986 05 1986 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $765 $400 Not Implemented
CO0052 # 06 Y:1986 06 1986 IMPROVE LUBRICATION PRACTICES $3,842 $0 Implemented
CO0052 # 07 Y:1986 07 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $111 $250 Not Implemented
CO0052 # 08 Y:1986 08 1986 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $73 $30 Implemented
CO0052 # 09 Y:1986 09 1986 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $3,902 $4,000 Implemented
CO0052 # 10 Y:1986 10 1986 INSTALL SET-BACK TIMERS $1,267 $657 Implemented
CO0050 # 01 Y:1985 01 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,161 $6,500 Not Implemented
CO0050 # 02 Y:1985 02 1985 INSTALL TIMERS AND/OR THERMOSTATS $16,221 $2,791 Implemented
CO0050 # 03 Y:1985 03 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $888 $200 Implemented
CO0050 # 04 Y:1985 04 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $159 $200 Implemented
CO0050 # 05 Y:1985 05 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,313 $1,600 Implemented
CO0050 # 06 Y:1985 06 1985 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $6,022 $1,570 Implemented
CO0050 # 07 Y:1985 07 1985 INSTALL STORM WINDOWS AND DOORS $985 $750 Not Implemented
CO0050 # 08 Y:1985 08 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,212 $800 Implemented
CO0050 # 09 Y:1985 09 1985 INSTALL TURBULATORS $793 $1,000 Not Implemented
CO0050 # 10 Y:1985 10 1985 IMPROVE LUBRICATION PRACTICES $157 $0 Not Implemented
CO0050 # 11 Y:1985 11 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $825 $3,564 Not Implemented
CO0044 # 01 Y:1985 01 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $9,425 $5,000 Not Implemented
CO0044 # 02 Y:1985 02 1985 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $2,324 $560 Implemented
CO0044 # 03 Y:1985 03 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,668 $100 Implemented
CO0044 # 04 Y:1985 04 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $368 $300 Not Implemented
CO0044 # 05 Y:1985 05 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $128 $200 Not Implemented
CO0044 # 06 Y:1985 06 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,521 $4,257 Not Implemented
CO0044 # 07 Y:1985 07 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $836 $1,714 Not Implemented