Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,456

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0024 # 03 Y:1985 03 1985 REPAIR AND ELIMINATE STEAM LEAKS $5,315 $2,000 Implemented
CO0024 # 04 Y:1985 04 1985 INSULATE BARE EQUIPMENT $454 $1,800 Not Implemented
CO0024 # 05 Y:1985 05 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $242 $100 Not Implemented
CO0024 # 06 Y:1985 06 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,838 $900 Implemented
CO0025 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,180 $2,587 Not Implemented
CO0025 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,791 $300 Implemented
CO0025 # 03 Y:1985 03 1985 INSTALL TIMERS AND/OR THERMOSTATS $1,650 $142 Not Implemented
CO0025 # 04 Y:1985 04 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,847 $400 Not Implemented
CO0025 # 05 Y:1985 05 1985 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $253 $100 Not Implemented
CO0025 # 06 Y:1985 06 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $117 $100 Not Implemented
CO0026 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,177 $6,312 Implemented
CO0026 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,652 $300 Implemented
CO0026 # 03 Y:1985 03 1985 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,931 $3,500 Not Implemented
CO0026 # 04 Y:1985 04 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $49 $50 Not Implemented
CO0026 # 05 Y:1985 05 1985 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $20,318 $25,000 Implemented
CO0026 # 06 Y:1985 06 1985 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $519 $3,500 Not Implemented
CO0026 # 07 Y:1985 07 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $932 $200 Not Implemented
CO0026 # 08 Y:1985 08 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $165 $200 Implemented
CO0026 # 09 Y:1985 09 1985 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $373 $2,000 Not Implemented
CO0021 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $474 $219 Implemented
CO0021 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $440 $500 Implemented
CO0021 # 03 Y:1985 03 1985 INSULATE BARE EQUIPMENT $811 $200 Implemented
CO0021 # 04 Y:1985 04 1985 INSULATE BARE EQUIPMENT $149 $200 Implemented
CO0021 # 05 Y:1985 05 1985 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $2,675 $0 Implemented
CO0021 # 06 Y:1985 06 1985 REDUCE LOAD ON ELECTRICAL CONDUCTOR TO REDUCE HEATING LOSSES $3,907 $1,000 Not Implemented