Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
160
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0117 # 06 Y:1988 | 06 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $56,432 | $60,000 | Not Implemented |
CO0095 # 01 Y:1987 | 01 | 1987 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $84,858 | $27,000 | Implemented |
CO0095 # 02 Y:1987 | 02 | 1987 | INCREASE AMOUNT OF CONDENSATE RETURNED | $19,460 | $1,000 | Implemented |
CO0095 # 03 Y:1987 | 03 | 1987 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $3,467 | $500 | Not Implemented |
CO0095 # 04 Y:1987 | 04 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $573 | $500 | Implemented |
CO0095 # 05 Y:1987 | 05 | 1987 | INSULATE BARE EQUIPMENT | $2,502 | $950 | Not Implemented |
CO0095 # 06 Y:1987 | 06 | 1987 | REPAIR AND ELIMINATE STEAM LEAKS | $4,535 | $250 | Implemented |
CO0095 # 07 Y:1987 | 07 | 1987 | INSTALL STEAM TRAP | $483 | $220 | Implemented |
CO0095 # 08 Y:1987 | 08 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $253 | $300 | Implemented |
CO0095 # 09 Y:1987 | 09 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $581 | $0 | Not Implemented |
CO0089 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,416 | $21 | Implemented |
CO0089 # 02 Y:1987 | 02 | 1987 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,026 | $150 | Implemented |
CO0089 # 03 Y:1987 | 03 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,537 | $500 | Implemented |
CO0089 # 04 Y:1987 | 04 | 1987 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $8,540 | $3,000 | Not Implemented |
CO0089 # 05 Y:1987 | 05 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $726 | $300 | Implemented |
CO0089 # 06 Y:1987 | 06 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $13,198 | $0 | Implemented |
CO0089 # 07 Y:1987 | 07 | 1987 | USE RADIANT HEATER FOR SPOT HEATING | $50,245 | $180,000 | Not Implemented |
CO0089 # 08 Y:1987 | 08 | 1987 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $19,113 | $24,000 | Implemented |
CO0089 # 09 Y:1987 | 09 | 1987 | AIR CONDITION ONLY SPACE NECESSARY | $8,911 | $2,100 | Not Implemented |
CO0089 # 10 Y:1987 | 10 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,042 | $7,140 | Not Implemented |
CO0089 # 11 Y:1987 | 11 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,916 | $13,440 | Not Implemented |
CO0089 # 12 Y:1987 | 12 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,066 | $750 | Implemented |
CO0089 # 13 Y:1987 | 13 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,437 | $1,000 | Implemented |
CO0089 # 14 Y:1987 | 14 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,473 | $750 | Implemented |
CO0089 # 15 Y:1987 | 15 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $479 | $300 | Implemented |