Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
419
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0213 # 01 Y:2022 | 01 | 2022 | ADJUST BURNERS FOR EFFICIENT OPERATION | $81,353 | $115,000 | Implemented |
DL0213 # 02 Y:2022 | 02 | 2022 | INSULATE BARE EQUIPMENT | $50,015 | $22,860 | Not Implemented |
DL0213 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,425 | $18,000 | Not Implemented |
DL0213 # 04 Y:2022 | 04 | 2022 | REPAIR OR REPLACE STEAM TRAPS | $92,874 | $102,000 | Implemented |
DL0199 # 01 Y:2021 | 01 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,226 | $0 | Implemented |
DL0199 # 02 Y:2021 | 02 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,784 | $0 | Implemented |
DL0199 # 03 Y:2021 | 03 | 2021 | REPAIR FAULTY LOUVERS AND DAMPERS | $2,440 | $2,275 | Not Implemented |
DL0199 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,657 | $1,514 | Implemented |
DL0199 # 05 Y:2021 | 05 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $341 | $805 | Not Implemented |
DL0199 # 06 Y:2021 | 06 | 2021 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $296 | $20 | Not Implemented |
DL0199 # 07 Y:2021 | 07 | 2021 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $280 | $1,170 | Not Implemented |
DL0199 # 08 Y:2021 | 08 | 2021 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $272 | $1,000 | Not Implemented |
DL0199 # 09 Y:2021 | 09 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $988 | $3,000 | Not Implemented |
DL0199 # 10 Y:2021 | 10 | 2021 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,675 | $7,837 | Not Implemented |
DL0199 # 11 Y:2021 | 11 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,626 | $20,387 | Not Implemented |
DL0199 # 12 Y:2021 | 12 | 2021 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $10,836 | $5,559 | Not Implemented |
DL0199 # 13 Y:2021 | 13 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,579 | $2,106 | Implemented |
DL0177 # 01 Y:2017 | 01 | 2017 | OPERATE BOILERS ON HIGH FIRE SETTING | $16,174 | $28,750 | Not Implemented |
DL0177 # 02 Y:2017 | 02 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,881 | $2,032 | Not Implemented |
DL0177 # 03 Y:2017 | 03 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $12,079 | $3,000 | Not Implemented |
DL0177 # 04 Y:2017 | 04 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $39,860 | $40,000 | Not Implemented |
DL0173 # 01 Y:2017 | 01 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $20,880 | $0 | Implemented |
DL0173 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,435 | $15,000 | Implemented |
DL0173 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,100 | $9,375 | Not Implemented |
DL0173 # 04 Y:2017 | 04 | 2017 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,676 | $1,375 | Implemented |