Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,142
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0237 # 01 Y:2024 | 01 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,341 | $0 | Implemented |
DL0237 # 02 Y:2024 | 02 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,667 | $0 | Implemented |
DL0237 # 03 Y:2024 | 03 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,998 | $0 | Implemented |
DL0237 # 04 Y:2024 | 04 | 2024 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,180 | $64 | Implemented |
DL0237 # 05 Y:2024 | 05 | 2024 | REDUCE VENTILATION AIR | $1,145 | $270 | Implemented |
DL0237 # 06 Y:2024 | 06 | 2024 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,985 | $4,000 | Implemented |
DL0237 # 07 Y:2024 | 07 | 2024 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $682 | $4,000 | Not Implemented |
DL0237 # 08 Y:2024 | 08 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $333 | $252 | Not Implemented |
DL0237 # 09 Y:2024 | 09 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,873 | $30,027 | Not Implemented |
DL0236 # 01 Y:2024 | 01 | 2024 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,849 | $0 | Not Implemented |
DL0236 # 02 Y:2024 | 02 | 2024 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $19,869 | $2,400 | Not Implemented |
DL0236 # 03 Y:2024 | 03 | 2024 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $3,343 | $1,500 | Not Implemented |
DL0236 # 04 Y:2024 | 04 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $4,721 | $1,500 | Not Implemented |
DL0236 # 05 Y:2024 | 05 | 2024 | INSTALL AUTOMATIC BOILER FUEL FEED SYSTEM | $18,917 | $52,500 | Not Implemented |
DL0236 # 06 Y:2024 | 06 | 2024 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,131 | $0 | Not Implemented |
DL0236 # 07 Y:2024 | 07 | 2024 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $22,162 | $53,200 | Not Implemented |
DL0236 # 08 Y:2024 | 08 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,945 | $28,600 | Not Implemented |
DL0236 # 09 Y:2024 | 09 | 2024 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $57,286 | $101,040 | Not Implemented |
DL0236 # 10 Y:2024 | 10 | 2024 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $23,405 | $56,000 | Not Implemented |
DL0236 # 11 Y:2024 | 11 | 2024 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $19,869 | $1,512 | Not Implemented |
DL0236 # 12 Y:2024 | 12 | 2024 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $6,300 | $3,500 | Not Implemented |
DL0235 # 01 Y:2024 | 01 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $719 | $0 | Implemented |
DL0235 # 02 Y:2024 | 02 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $751 | $800 | Not Implemented |
DL0235 # 03 Y:2024 | 03 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,885 | $500 | Not Implemented |
DL0235 # 04 Y:2024 | 04 | 2024 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $24,674 | $10,000 | Implemented |