Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
163
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0135 # 07 Y:2014 | 07 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,400 | $0 | Implemented |
DL0135 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,230 | $0 | Not Implemented |
DL0134 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,090 | $10,500 | Not Implemented |
DL0134 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,000 | $33,600 | Implemented |
DL0134 # 08 Y:2014 | 08 | 2014 | METER WASTE WATER | $8,610 | $8,200 | Implemented |
DL0134 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,580 | $0 | Implemented |
DL0134 # 05 Y:2014 | 05 | 2014 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $54,210 | $28,110 | Not Implemented |
DL0134 # 04 Y:2014 | 04 | 2014 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $4,630 | $5,700 | Not Implemented |
DL0134 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,200 | $13,590 | Not Implemented |
DL0134 # 02 Y:2014 | 02 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $41,430 | $54,000 | Implemented |
DL0133 # 07 Y:2014 | 07 | 2014 | INSTALL AUTOMATIC STACK DAMPER | $3,680 | $550 | Not Implemented |
DL0133 # 10 Y:2014 | 10 | 2014 | REDUCE VENTILATION AIR | $182 | $235 | Not Implemented |
DL0133 # 09 Y:2014 | 09 | 2014 | REDUCE VENTILATION AIR | $1,110 | $0 | Not Implemented |
DL0133 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,710 | $26,460 | Not Implemented |
DL0133 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,170 | $4,000 | Not Implemented |
DL0133 # 04 Y:2014 | 04 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $7,800 | $6,000 | Not Implemented |
DL0133 # 08 Y:2014 | 08 | 2014 | RECOVER AND REUSE COOLING WATER | $5,180 | $15,600 | Not Implemented |
DL0133 # 02 Y:2014 | 02 | 2014 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $11,540 | $18,000 | Not Implemented |
DL0133 # 03 Y:2014 | 03 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,385 | $0 | Not Implemented |
DL0133 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $63,690 | $134,000 | Not Implemented |
DL0132 # 09 Y:2014 | 09 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,580 | $7,000 | Not Implemented |
DL0132 # 08 Y:2014 | 08 | 2014 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,350 | $1,600 | Not Implemented |
DL0132 # 04 Y:2014 | 04 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $11,450 | $1,000 | Implemented |
DL0132 # 03 Y:2014 | 03 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,657 | $2,600 | Not Implemented |
DL0132 # 07 Y:2014 | 07 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,920 | $1,000 | Implemented |