Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
273
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0772 # 05 Y:2003 | 05 | 2003 | RECOVER AND REUSE COOLING WATER | $13,569 | $12,000 | n/a |
GT0772 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,490 | $6,340 | Implemented |
GT0772 # 02 Y:2003 | 02 | 2003 | INSULATE BARE EQUIPMENT | $354 | $248 | Not Implemented |
GT0772 # 03 Y:2003 | 03 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,848 | $0 | Implemented |
GT0772 # 04 Y:2003 | 04 | 2003 | COMBINE UTILITY METERS | $113,960 | $0 | Not Implemented |
GT0772 # 08 Y:2003 | 08 | 2003 | USE SOLAR HEAT FOR HEAT | $872 | $490 | Not Implemented |
GT0772 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $130 | $50 | Not Implemented |
GT0771 # 05 Y:2003 | 05 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $28,826 | $1,248 | Not Implemented |
GT0771 # 06 Y:2003 | 06 | 2003 | COVER OPEN TANKS | $3,255 | $3,703 | Not Implemented |
GT0771 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,260 | $1,050 | Implemented |
GT0771 # 08 Y:2003 | 08 | 2003 | COVER OPEN TANKS | $23,765 | $700 | Not Implemented |
GT0771 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $29,561 | $12,093 | Not Implemented |
GT0771 # 02 Y:2003 | 02 | 2003 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $17,568 | $23,870 | Implemented |
GT0771 # 03 Y:2003 | 03 | 2003 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $882 | $650 | Implemented |
GT0771 # 10 Y:2003 | 10 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,823 | $0 | Not Implemented |
GT0771 # 07 Y:2003 | 07 | 2003 | COVER OPEN TANKS | $2,447 | $3,500 | Not Implemented |
GT0771 # 01 Y:2003 | 01 | 2003 | COMBINE UTILITY METERS | $3,600 | $0 | Implemented |
GT0767 # 09 Y:2003 | 09 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,680 | $3,286 | Not Implemented |
GT0767 # 07 Y:2003 | 07 | 2003 | INSULATE BARE EQUIPMENT | $2,095 | $3,863 | Not Implemented |
GT0767 # 05 Y:2003 | 05 | 2003 | USE OPTIMUM TEMPERATURE | $9,365 | $5,650 | Not Implemented |
GT0767 # 10 Y:2003 | 10 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,963 | $54,960 | n/a |
GT0767 # 08 Y:2003 | 08 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $25,099 | $11,100 | Not Implemented |
GT0767 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $2,317 | $298 | Not Implemented |
GT0769 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $3,157 | $2,000 | n/a |
GT0769 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,869 | $2,137 | n/a |