Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
396
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
HO0186 # 05 Y:1998 | 05 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $11,162 | $5,000 | Implemented |
HO0186 # 04 Y:1998 | 04 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,873 | $3,000 | Implemented |
HO0186 # 03 Y:1998 | 03 | 1998 | USE RADIANT HEATER FOR SPOT HEATING | $6,903 | $6,000 | Not Implemented |
HO0186 # 02 Y:1998 | 02 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,988 | $0 | Implemented |
HO0186 # 01 Y:1998 | 01 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $268 | $0 | Implemented |
HO0183 # 09 Y:1998 | 09 | 1998 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $5,840 | $800 | Not Implemented |
HO0183 # 08 Y:1998 | 08 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $11,680 | $0 | Not Implemented |
HO0183 # 07 Y:1998 | 07 | 1998 | INSTALL BACK-UP EQUIPMENT | $3,040 | $8,000 | Not Implemented |
HO0183 # 06 Y:1998 | 06 | 1998 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,620 | $3,000 | Implemented |
HO0183 # 05 Y:1998 | 05 | 1998 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $6,570 | $27,500 | Not Implemented |
HO0183 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $225 | $250 | Implemented |
HO0183 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $297 | $552 | Not Implemented |
HO0183 # 02 Y:1998 | 02 | 1998 | ADD AREA LIGHTING SWITCHES | $621 | $500 | Implemented |
HO0183 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,829 | $7,483 | Not Implemented |
HO0180 # 04 Y:1998 | 04 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $36,720 | $30,000 | Not Implemented |
HO0180 # 03 Y:1998 | 03 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $2,004 | $1,000 | Implemented |
HO0180 # 02 Y:1998 | 02 | 1998 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $1,852 | $0 | Not Implemented |
HO0180 # 01 Y:1998 | 01 | 1998 | BURN A LESS EXPENSIVE GRADE OF FUEL | $3,722 | $0 | Not Implemented |
HO0179 # 09 Y:1998 | 09 | 1998 | MINIMIZE WATER USAGE | $338 | $900 | Not Implemented |
HO0179 # 08 Y:1998 | 08 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $2,880 | $200 | Implemented |
HO0179 # 07 Y:1998 | 07 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $20,000 | $35,000 | Not Implemented |
HO0179 # 06 Y:1998 | 06 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,070 | $5,550 | Not Implemented |
HO0179 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,874 | $2,420 | Implemented |
HO0179 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $622 | $1,400 | Implemented |
HO0179 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,131 | $1,493 | Not Implemented |