Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,057
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0429 # 02 Y:2008 | 02 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,875 | $45 | Implemented |
IA0429 # 03 Y:2008 | 03 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $620 | $480 | Not Implemented |
IA0429 # 04 Y:2008 | 04 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $170 | $190 | Implemented |
IA0429 # 05 Y:2008 | 05 | 2008 | INSTALL SPECTRAL REFLECTORS / DELAMP | $460 | $68 | Not Implemented |
IA0429 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $1,353 | $2,424 | Implemented |
IA0429 # 07 Y:2008 | 07 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,292 | $2,641 | Implemented |
IA0429 # 08 Y:2008 | 08 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $481 | $350 | Implemented |
IA0429 # 09 Y:2008 | 09 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $1,842 | $25,870 | Implemented |
IA0426 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,200 | $10,307 | Implemented |
IA0426 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $678 | $847 | Implemented |
IA0426 # 03 Y:2008 | 03 | 2008 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,565 | $225 | Implemented |
IA0426 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,748 | $2,450 | Implemented |
IA0426 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,526 | $30 | Not Implemented |
IA0426 # 06 Y:2008 | 06 | 2008 | PAY UTILITY BILLS ON TIME | $16,112 | $0 | Implemented |
IA0426 # 07 Y:2008 | 07 | 2008 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $4,743 | $185 | Implemented |
IA0426 # 08 Y:2008 | 08 | 2008 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $7,288 | $3,550 | Not Implemented |
IA0426 # 09 Y:2008 | 09 | 2008 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $4,110 | $10,000 | Not Implemented |
IA0426 # 10 Y:2008 | 10 | 2008 | OPTIMIZE PLANT POWER FACTOR | $64,666 | $43,320 | Not Implemented |
IA0426 # 11 Y:2008 | 11 | 2008 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $28,890 | $8,900 | Implemented |
IA0425 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $1,843 | $600 | Not Implemented |
IA0425 # 02 Y:2008 | 02 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,124 | $640 | Not Implemented |
IA0425 # 03 Y:2008 | 03 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $15,476 | $600 | Implemented |
IA0425 # 04 Y:2008 | 04 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $50,635 | $291,629 | Implemented |
IA0425 # 05 Y:2008 | 05 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,405 | $6,450 | Not Implemented |
IA0425 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,859 | $2,000 | Implemented |