IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,660

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0465 # 08 Y:2011 08 2011 USE RADIANT HEATER FOR SPOT HEATING $20,214 $48,000 Not Implemented
IA0464 # 01 Y:2011 01 2011 REPAIR AND ELIMINATE STEAM LEAKS $1,766 $700 Implemented
IA0464 # 02 Y:2011 02 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $387 $290 Implemented
IA0464 # 03 Y:2011 03 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $380 $15 Implemented
IA0464 # 04 Y:2011 04 2011 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,199 $45 Implemented
IA0464 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,295 $10,281 Implemented
IA0464 # 06 Y:2011 06 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,737 $33,313 Implemented
IA0464 # 07 Y:2011 07 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,378 $7,606 Implemented
IA0463 # 01 Y:2011 01 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,055 $500 Not Implemented
IA0463 # 02 Y:2011 02 2011 USE PHOTOCELL CONTROLS $361 $235 Not Implemented
IA0463 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,748 $3,095 Not Implemented
IA0463 # 04 Y:2011 04 2011 INSTALL OCCUPANCY SENSORS $907 $760 Not Implemented
IA0463 # 05 Y:2011 05 2011 REPAIR AND ELIMINATE STEAM LEAKS $4,181 $3,000 Not Implemented
IA0463 # 06 Y:2011 06 2011 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,257 $50 Not Implemented
IA0463 # 07 Y:2011 07 2011 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $281 $754 Not Implemented
IA0462 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,158 $15,702 Not Implemented
IA0462 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,704 $16,590 Not Implemented
IA0462 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $2,818 $1,530 Not Implemented
IA0462 # 04 Y:2011 04 2011 UTILIZE A LESS EXPENSIVE COOLING METHOD $59,656 $20,000 Not Implemented
IA0462 # 05 Y:2011 05 2011 RECOVER WASTE HEAT FROM EQUIPMENT $15,983 $25,000 Not Implemented
IA0462 # 06 Y:2011 06 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,698 $240 Not Implemented
IA0462 # 07 Y:2011 07 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,593 $250 Not Implemented
IA0462 # 08 Y:2011 08 2011 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $22,774 $1,500 Not Implemented
IA0462 # 09 Y:2011 09 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,450 $1,000 Not Implemented
IA0462 # 10 Y:2011 10 2011 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,518 $200 Not Implemented