Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,217
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0309 # 08 Y:1990 | 08 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,990 | $2,400 | Implemented |
KU0310 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,155 | $4,288 | Implemented |
KU0310 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,513 | $280 | Implemented |
KU0307 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,882 | $1,861 | Implemented |
KU0307 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $503 | $0 | Implemented |
KU0307 # 03 Y:1990 | 03 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $235 | $50 | Not Implemented |
KU0307 # 04 Y:1990 | 04 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $140 | $0 | Implemented |
KU0307 # 05 Y:1990 | 05 | 1990 | USE MINIMUM SAFE OVEN VENTILATION | $4,979 | $600 | Implemented |
KU0307 # 06 Y:1990 | 06 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $250 | $0 | Implemented |
KU0307 # 07 Y:1990 | 07 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,730 | $14,000 | Implemented |
KU0299 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $421 | $121 | Implemented |
KU0299 # 02 Y:1989 | 02 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $447 | $250 | Implemented |
KU0299 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $315 | $150 | Not Implemented |
KU0299 # 04 Y:1989 | 04 | 1989 | REPAIR OR REPLACE STEAM TRAPS | $8,388 | $450 | Implemented |
KU0299 # 05 Y:1989 | 05 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,205 | $2,400 | Not Implemented |
KU0299 # 06 Y:1989 | 06 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $1,466 | $1,700 | Not Implemented |
KU0299 # 07 Y:1989 | 07 | 1989 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $258 | $0 | Implemented |
KU0299 # 08 Y:1989 | 08 | 1989 | INSULATE BARE EQUIPMENT | $183 | $280 | Not Implemented |
KU0295 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $390 | $576 | Implemented |
KU0295 # 02 Y:1989 | 02 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,793 | $3,300 | Implemented |
KU0295 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,741 | $5,300 | Implemented |
KU0295 # 04 Y:1989 | 04 | 1989 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,301 | $150 | Implemented |
KU0295 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,066 | $0 | Implemented |
KU0295 # 06 Y:1989 | 06 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $238 | $200 | Not Implemented |
KU0295 # 07 Y:1989 | 07 | 1989 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $120 | $200 | Not Implemented |