Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0254 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $5,323 | $1,185 | Not Implemented |
LL0254 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,656 | $1,920 | Not Implemented |
LL0254 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $867 | $555 | Not Implemented |
LL0254 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $94 | $102 | Not Implemented |
LL0260 # 01 Y:2006 | 01 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $11,704 | $5,420 | Implemented |
LL0260 # 02 Y:2006 | 02 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,890 | $5,109 | Not Implemented |
LL0260 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,503 | $3,652 | Not Implemented |
LL0260 # 04 Y:2006 | 04 | 2006 | USE PHOTOCELL CONTROLS | $3,127 | $630 | Not Implemented |
LL0260 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,371 | $600 | Implemented |
LL0260 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,087 | $770 | Implemented |
LL0260 # 07 Y:2006 | 07 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $756 | $359 | Not Implemented |
LL0260 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $751 | $600 | Not Implemented |
LL0258 # 01 Y:2006 | 01 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $3,668,421 | $1,500,000 | Not Implemented |
LL0258 # 02 Y:2006 | 02 | 2006 | USE PHOTOCELL CONTROLS | $68,323 | $3,630 | Implemented |
LL0258 # 03 Y:2006 | 03 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $65,870 | $8,195 | Not Implemented |
LL0258 # 04 Y:2006 | 04 | 2006 | USE PHOTOCELL CONTROLS | $27,638 | $4,050 | Implemented |
LL0258 # 05 Y:2006 | 05 | 2006 | INSTALL OCCUPANCY SENSORS | $18,294 | $2,190 | Not Implemented |
LL0258 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,321 | $3,850 | Not Implemented |
LL0258 # 07 Y:2006 | 07 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $755 | $432 | Not Implemented |
LL0257 # 01 Y:2006 | 01 | 2006 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $501,312 | $98,000 | Not Implemented |
LL0257 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $302,971 | $5,510 | Not Implemented |
LL0257 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,217 | $7,960 | Not Implemented |
LL0257 # 04 Y:2006 | 04 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,875 | $810 | Not Implemented |
LL0257 # 05 Y:2006 | 05 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $10,380 | $18,000 | Not Implemented |
LL0257 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $5,404 | $5,120 | Not Implemented |