Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2006
Principal Product Carbon Black
NAICS 325180 - Other Basic Inorganic Chemical Manufacturing
SIC 2895 - Carbon Black
Sales $100,000,000-$500,000,000
# of Employees 150
Plant Area (Sq.Ft.) 250,000
Annual Production 140,000 Tons
Production Hrs. Annual 8,736
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $4,228,265 61,844,550 kWh $0.07
Electricity Demand $753,234 101,939 kW-months/year $7.39
Electricity Fees $184,944 - $ -
Natural Gas $19,016,134 2,048,426 MMBtu $9.28
TOTAL ENERGY COSTS $24,182,577
RECOMMENDED SAVINGS* $3,855,622 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $95,961
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes
$ kWh $ kW-months/year $ $ $ MMBtu $ $
01: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL Savings:
$3,668,421
Cost:
$1,500,000
- - - - - - $3,668,421 395,304 - - -
-
kWh
-
-
kW-months/year
-
-
$
$3,668,421
395,304
MMBtu
-
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$68,323
Cost:
$3,630
$65,883 963,203 - - $2,440 - - - - - $65,883
963,203
kWh
-
-
kW-months/year
$2,440
-
$
-
-
MMBtu
-
-
$
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$65,870
Cost:
$8,195
$63,517 928,612 - - $2,353 - - - - - $63,517
928,612
kWh
-
-
kW-months/year
$2,353
-
$
-
-
MMBtu
-
-
$
04: 2.7134 USE PHOTOCELL CONTROLS Savings:
$27,638
Cost:
$4,050
$26,651 389,631 - - $987 - - - - - $26,651
389,631
kWh
-
-
kW-months/year
$987
-
$
-
-
MMBtu
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$18,294
Cost:
$2,190
$17,641 257,904 - - $653 - - - - - $17,641
257,904
kWh
-
-
kW-months/year
$653
-
$
-
-
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,321
Cost:
$3,850
$2,505 36,617 $370 50 $106 - - - $3,340 - $2,505
36,617
kWh
$370
50
kW-months/year
$106
-
$
-
-
MMBtu
$3,340
-
$
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$755
Cost:
$432
$447 6,529 $281 38 $27 - - - - - $447
6,529
kWh
$281
38
kW-months/year
$27
-
$
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$3,855,622
Cost:
$1,522,347
$176,644 2,582,496 $651 88 $6,566 - $3,668,421 395,304 $3,340 - $176,644
2,582,496
kWh
$651
88
kW-months/year
$6,566
-
$
$3,668,421
395,304
MMBtu
$3,340
-
$
TOTAL IMPLEMENTED Savings:
$95,961
Cost:
$7,680
$92,534 1,352,834 - - $3,427 - - - - - $92,534
1,352,834
kWh
-
-
kW-months/year
$3,427
-
$
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Personnel Changes