Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2006 |
Principal Product | Carbon Black |
NAICS | 325180 - Other Basic Inorganic Chemical Manufacturing |
SIC | 2895 - Carbon Black |
Sales | $100,000,000-$500,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 140,000 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $4,228,265 | 61,844,550 | kWh | $0.07 |
Electricity Demand | $753,234 | 101,939 | kW-months/year | $7.39 |
Electricity Fees | $184,944 | - | $ | - |
Natural Gas | $19,016,134 | 2,048,426 | MMBtu | $9.28 |
TOTAL ENERGY COSTS | $24,182,577 | |||
RECOMMENDED SAVINGS* | $3,855,622 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $95,961 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL |
Savings: $3,668,421 Cost: $1,500,000 |
- | - | - | - | - | - | $3,668,421 | 395,304 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,668,421 395,304 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $68,323 Cost: $3,630 |
$65,883 | 963,203 | - | - | $2,440 | - | - | - | - | - |
$65,883 963,203 kWh |
- - kW-months/year |
$2,440 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $65,870 Cost: $8,195 |
$63,517 | 928,612 | - | - | $2,353 | - | - | - | - | - |
$63,517 928,612 kWh |
- - kW-months/year |
$2,353 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $27,638 Cost: $4,050 |
$26,651 | 389,631 | - | - | $987 | - | - | - | - | - |
$26,651 389,631 kWh |
- - kW-months/year |
$987 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $18,294 Cost: $2,190 |
$17,641 | 257,904 | - | - | $653 | - | - | - | - | - |
$17,641 257,904 kWh |
- - kW-months/year |
$653 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,321 Cost: $3,850 |
$2,505 | 36,617 | $370 | 50 | $106 | - | - | - | $3,340 | - |
$2,505 36,617 kWh |
$370 50 kW-months/year |
$106 - $ |
- - MMBtu |
$3,340 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $755 Cost: $432 |
$447 | 6,529 | $281 | 38 | $27 | - | - | - | - | - |
$447 6,529 kWh |
$281 38 kW-months/year |
$27 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $3,855,622 Cost: $1,522,347 |
$176,644 | 2,582,496 | $651 | 88 | $6,566 | - | $3,668,421 | 395,304 | $3,340 | - | $176,644 2,582,496 kWh |
$651 88 kW-months/year |
$6,566 - $ |
$3,668,421 395,304 MMBtu |
$3,340 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $95,961 Cost: $7,680 |
$92,534 | 1,352,834 | - | - | $3,427 | - | - | - | - | - | $92,534 1,352,834 kWh |
- - kW-months/year |
$3,427 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes |