Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0194 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,957 | $570 | Implemented |
LL0194 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,000 | $2,360 | Implemented |
LL0194 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,025 | $770 | Implemented |
LL0194 # 05 Y:2004 | 05 | 2004 | USE PHOTOCELL CONTROLS | $729 | $60 | Implemented |
LL0194 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $419 | $180 | Implemented |
LL0194 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $764 | $158 | Implemented |
LL0193 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $118,511 | $3,400 | Implemented |
LL0193 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $16,033 | $25,871 | Implemented |
LL0193 # 03 Y:2004 | 03 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $12,157 | $1,671 | Not Implemented |
LL0193 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,526 | $390 | Implemented |
LL0193 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $195 | $135 | Implemented |
LL0193 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $350 | Implemented |
LL0193 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,980 | $1,684 | Implemented |
LL0192 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $61,254 | $2,590 | Implemented |
LL0192 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $55,907 | $0 | Not Implemented |
LL0192 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $41,577 | $4,400 | Implemented |
LL0192 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $21,326 | $420 | Not Implemented |
LL0192 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,708 | $2,585 | Implemented |
LL0192 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $3,529 | $720 | Not Implemented |
LL0192 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $2,881 | $911 | Not Implemented |
LL0192 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,610 | $6,030 | Not Implemented |
LL0191 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $23,552 | $3,917 | Not Implemented |
LL0191 # 02 Y:2004 | 02 | 2004 | USE PHOTOCELL CONTROLS | $10,938 | $420 | Implemented |
LL0191 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,388 | $4,960 | Implemented |
LL0191 # 04 Y:2004 | 04 | 2004 | COMBINE UTILITY METERS | $2,825 | $420 | Not Implemented |