Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,718
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0146 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,890 | $2,580 | Implemented |
LL0146 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,680 | $0 | Not Implemented |
LL0146 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,286 | $0 | Not Implemented |
LL0146 # 05 Y:2002 | 05 | 2002 | USE PHOTOCELL CONTROLS | $205 | $52 | Not Implemented |
LL0146 # 06 Y:2002 | 06 | 2002 | USE PHOTOCELL CONTROLS | $102 | $41 | Not Implemented |
LL0146 # 07 Y:2002 | 07 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,720 | $2,400 | Implemented |
LL0150 # 01 Y:2002 | 01 | 2002 | OPTIMIZE PLANT POWER FACTOR | $6,951 | $9,520 | Not Implemented |
LL0150 # 02 Y:2002 | 02 | 2002 | USE PHOTOCELL CONTROLS | $3,964 | $416 | Not Implemented |
LL0150 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,671 | $0 | Implemented |
LL0150 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $762 | $78 | Not Implemented |
LL0150 # 05 Y:2002 | 05 | 2002 | USE PHOTOCELL CONTROLS | $460 | $52 | Not Implemented |
LL0150 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $312 | $52 | Not Implemented |
LL0150 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $200 | $260 | Not Implemented |
LL0150 # 08 Y:2002 | 08 | 2002 | INSTALL OCCUPANCY SENSORS | $198 | $52 | Not Implemented |
LL0150 # 09 Y:2002 | 09 | 2002 | INSTALL OCCUPANCY SENSORS | $198 | $52 | Not Implemented |
LL0150 # 10 Y:2002 | 10 | 2002 | INSTALL OCCUPANCY SENSORS | $154 | $52 | Not Implemented |
LL0149 # 01 Y:2002 | 01 | 2002 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $1,932 | $1,499 | Implemented |
LL0149 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,591 | $210 | Not Implemented |
LL0149 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,237 | $0 | Not Implemented |
LL0149 # 04 Y:2002 | 04 | 2002 | INSTALL SKYLIGHTS | $1,206 | $1,660 | Implemented |
LL0149 # 05 Y:2002 | 05 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,505 | $2,255 | Implemented |
LL0145 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,490 | $1,350 | Implemented |
LL0145 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,323 | $0 | Implemented |
LL0145 # 03 Y:2002 | 03 | 2002 | OPTIMIZE PLANT POWER FACTOR | $5,861 | $6,125 | Implemented |
LL0145 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $486 | $104 | Implemented |