Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
533
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LT0053 # 05 Y:1986 | 05 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $2,214 | $2,000 | Implemented |
LT0053 # 08 Y:1986 | 08 | 1986 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $408 | $1,000 | Implemented |
LT0055 # 01 Y:1986 | 01 | 1986 | INSULATE BARE EQUIPMENT | $287 | $270 | Implemented |
LT0055 # 03 Y:1986 | 03 | 1986 | USE OPTIMUM THICKNESS INSULATION | $4,130 | $5,659 | Implemented |
LT0055 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,847 | $16,480 | Implemented |
LT0056 # 01 Y:1986 | 01 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $201 | $300 | Implemented |
LT0056 # 03 Y:1986 | 03 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $787 | $197 | Implemented |
LT0056 # 04 Y:1986 | 04 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $231 | $160 | Implemented |
LT0056 # 05 Y:1986 | 05 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $232 | $225 | Implemented |
LT0056 # 06 Y:1986 | 06 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $643 | $84 | Implemented |
LT0051 # 01 Y:1986 | 01 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,015 | $0 | Implemented |
LT0051 # 02 Y:1986 | 02 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,452 | $0 | Implemented |
LT0051 # 04 Y:1986 | 04 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $848 | $140 | Implemented |
LT0051 # 05 Y:1986 | 05 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,025 | $113 | Implemented |
LT0051 # 07 Y:1986 | 07 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,034 | $422 | Implemented |
LT0051 # 08 Y:1986 | 08 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,250 | $0 | Implemented |
LT0028 # 02 Y:1985 | 02 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,990 | $0 | Implemented |
LT0028 # 03 Y:1985 | 03 | 1985 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,165 | $0 | Implemented |
LT0028 # 04 Y:1985 | 04 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,628 | $120 | Implemented |
LT0028 # 05 Y:1985 | 05 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $116 | $150 | Implemented |
LT0029 # 01 Y:1985 | 01 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $170 | $111 | Implemented |
LT0029 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $2,230 | $450 | Implemented |
LT0029 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $713 | $150 | Implemented |
LT0043 # 01 Y:1985 | 01 | 1985 | INSTALL SET-BACK TIMERS | $338 | $0 | Implemented |
LT0043 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $901 | $300 | Implemented |