Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,692

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0060 # 09 Y:1986 09 1986 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $808 $2,200 Not Implemented
MA0061 # 01 Y:1986 01 1986 USE RADIANT HEATER FOR SPOT HEATING $721 $800 Implemented
MA0061 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,705 $300 Implemented
MA0061 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,390 $300 Implemented
MA0061 # 04 Y:1986 04 1986 INSTALL STORM WINDOWS AND DOORS $2,523 $6,945 Implemented
MA0057 # 01 Y:1986 01 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,191 $2,500 Implemented
MA0057 # 02 Y:1986 02 1986 REDUCE GLAZED AREAS IN BUILDINGS $3,959 $8,455 Implemented
MA0057 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $377 $300 Implemented
MA0057 # 04 Y:1986 04 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,512 $0 Not Implemented
MA0057 # 05 Y:1986 05 1986 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $2,262 $7,500 Implemented
MA0058 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,060 $90 Implemented
MA0058 # 02 Y:1986 02 1986 INSULATE BARE EQUIPMENT $3,740 $5,760 Implemented
MA0058 # 03 Y:1986 03 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,028 $0 Implemented
MA0059 # 01 Y:1986 01 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $6,336 $3,400 Implemented
MA0059 # 02 Y:1986 02 1986 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,030 $2,025 Not Implemented
MA0059 # 03 Y:1986 03 1986 INSTALL TIMERS AND/OR THERMOSTATS $3,217 $2,300 Implemented
MA0056 # 01 Y:1986 01 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,510 $2,500 Implemented
MA0056 # 02 Y:1986 02 1986 COVER OPEN TANKS $157 $0 Implemented
MA0056 # 03 Y:1986 03 1986 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,812 $1,700 Implemented
MA0056 # 04 Y:1986 04 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $566 $109 Not Implemented
MA0056 # 05 Y:1986 05 1986 INSTALL TIMERS AND/OR THERMOSTATS $2,380 $1,200 Implemented
MA0056 # 06 Y:1986 06 1986 INSTALL STORM WINDOWS AND DOORS $1,206 $1,760 Not Implemented
MA0056 # 07 Y:1986 07 1986 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $6,965 $0 Not Implemented
MA0053 # 01 Y:1986 01 1986 RECOVER WASTE HEAT FROM EQUIPMENT $8,920 $8,800 Not Implemented
MA0053 # 02 Y:1986 02 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,056 $850 Not Implemented