Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,692
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0041 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $192 | $143 | Implemented |
MA0042 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,464 | $200 | Implemented |
MA0042 # 02 Y:1985 | 02 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,060 | $24,450 | Implemented |
MA0042 # 03 Y:1985 | 03 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $326 | $280 | Implemented |
MA0042 # 04 Y:1985 | 04 | 1985 | OPTIMIZE PLANT POWER FACTOR | $9,522 | $13,420 | Implemented |
MA0042 # 05 Y:1985 | 05 | 1985 | IMPROVE LUBRICATION PRACTICES | $194 | $147 | Not Implemented |
MA0042 # 06 Y:1985 | 06 | 1985 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $9,886 | $0 | Implemented |
MA0036 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,352 | $550 | Not Implemented |
MA0036 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,279 | $476 | Not Implemented |
MA0036 # 03 Y:1985 | 03 | 1985 | DISCONNECT BALLASTS | $2,457 | $1,250 | Not Implemented |
MA0036 # 04 Y:1985 | 04 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $450 | $1,200 | Not Implemented |
MA0036 # 05 Y:1985 | 05 | 1985 | BURN WASTE PAPER FOR HEAT | $9,651 | $9,075 | Not Implemented |
MA0036 # 06 Y:1985 | 06 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,006 | $2,027 | Not Implemented |
MA0036 # 07 Y:1985 | 07 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,548 | $15,000 | Not Implemented |
MA0037 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,470 | $452 | Implemented |
MA0037 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $977 | $1,500 | Implemented |
MA0037 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,228 | $400 | Implemented |
MA0037 # 04 Y:1985 | 04 | 1985 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,309 | $11,314 | Implemented |
MA0037 # 05 Y:1985 | 05 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,730 | $400 | Implemented |
MA0037 # 06 Y:1985 | 06 | 1985 | REPAIR OR REPLACE STEAM TRAPS | $3,789 | $533 | Implemented |
MA0037 # 07 Y:1985 | 07 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,893 | $27,500 | Not Implemented |
MA0038 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,045 | $300 | Implemented |
MA0038 # 02 Y:1985 | 02 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,400 | $2,938 | Implemented |
MA0038 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $892 | $112 | Implemented |
MA0038 # 04 Y:1985 | 04 | 1985 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,867 | $500 | Implemented |