Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,209
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0071 # 07 Y:1986 | 07 | 1986 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,326 | $15,600 | Implemented |
MA0071 # 08 Y:1986 | 08 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,104 | $6,688 | Implemented |
MA0072 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,220 | $200 | Implemented |
MA0072 # 02 Y:1986 | 02 | 1986 | REPAIR OR REPLACE STEAM TRAPS | $13,251 | $600 | Implemented |
MA0072 # 03 Y:1986 | 03 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $34,923 | $1,500 | Implemented |
MA0072 # 04 Y:1986 | 04 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,691 | $720 | Implemented |
MA0072 # 05 Y:1986 | 05 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,992 | $6,740 | Implemented |
MA0072 # 06 Y:1986 | 06 | 1986 | KEEP BOILER TUBES CLEAN | $3,296 | $750 | Implemented |
MA0062 # 01 Y:1986 | 01 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,443 | $20,000 | Implemented |
MA0062 # 02 Y:1986 | 02 | 1986 | COVER OPEN TANKS | $1,079 | $605 | Not Implemented |
MA0062 # 03 Y:1986 | 03 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,903 | $2,200 | Not Implemented |
MA0062 # 04 Y:1986 | 04 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $202 | $140 | Implemented |
MA0062 # 05 Y:1986 | 05 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $446 | $30 | Implemented |
MA0063 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $325 | $60 | Implemented |
MA0063 # 02 Y:1986 | 02 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $282 | $100 | Not Implemented |
MA0063 # 03 Y:1986 | 03 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $428 | $586 | Implemented |
MA0063 # 04 Y:1986 | 04 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,963 | $450 | Implemented |
MA0063 # 05 Y:1986 | 05 | 1986 | REPAIR OR REPLACE STEAM TRAPS | $5,083 | $200 | Implemented |
MA0063 # 06 Y:1986 | 06 | 1986 | USE EXISTING DAM TO GENERATE ELECTRICITY | $36,671 | $180,000 | Not Implemented |
MA0059 # 01 Y:1986 | 01 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,336 | $3,400 | Implemented |
MA0059 # 02 Y:1986 | 02 | 1986 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,030 | $2,025 | Not Implemented |
MA0059 # 03 Y:1986 | 03 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $3,217 | $2,300 | Implemented |
MA0056 # 01 Y:1986 | 01 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,510 | $2,500 | Implemented |
MA0056 # 02 Y:1986 | 02 | 1986 | COVER OPEN TANKS | $157 | $0 | Implemented |
MA0056 # 03 Y:1986 | 03 | 1986 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,812 | $1,700 | Implemented |