IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

240

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0576 # 04 Y:2005 04 2005 RECOVER WASTE HEAT FROM EQUIPMENT $2,505 $4,283 Implemented
MA0567 # 01 Y:2004 01 2004 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $70,900 $270,000 Implemented
MA0567 # 02 Y:2004 02 2004 RECOVER WASTE HEAT FROM EQUIPMENT $61,633 $54,474 Not Implemented
MA0567 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,220 $11,950 Not Implemented
MA0567 # 04 Y:2004 04 2004 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $8,762 $1,000 Implemented
MA0567 # 05 Y:2004 05 2004 INSULATE BARE EQUIPMENT $4,156 $6,867 Implemented
MA0567 # 06 Y:2004 06 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $3,942 $5,000 Not Implemented
MA0567 # 07 Y:2004 07 2004 INSULATE BARE EQUIPMENT $1,615 $1,369 Implemented
MA0535 # 01 Y:2003 01 2003 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $372,126 $3,870,145 n/a
MA0535 # 02 Y:2003 02 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $67,147 $59,125 n/a
MA0535 # 03 Y:2003 03 2003 REDUCE VENTILATION AIR $62,192 $0 Not Implemented
MA0535 # 04 Y:2003 04 2003 UPGRADE CONTROLS ON COMPRESSORS $56,908 $84,343 n/a
MA0535 # 05 Y:2003 05 2003 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,274 $6,000 Not Implemented
MA0535 # 06 Y:2003 06 2003 RECOVER WASTE HEAT FROM EQUIPMENT $3,836 $11,700 n/a
MA0535 # 07 Y:2003 07 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,511 $5,800 Not Implemented
MA0535 # 08 Y:2003 08 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,521 $9,300 Not Implemented
MA0535 # 09 Y:2003 09 2003 INSULATE BARE EQUIPMENT $1,685 $864 Not Implemented
MA0535 # 10 Y:2003 10 2003 OPTIMIZE PLANT POWER FACTOR $1,303 $0 Implemented
MA0535 # 11 Y:2003 11 2003 USE PHOTOCELL CONTROLS $1,058 $1,058 Not Implemented
MA0535 # 12 Y:2003 12 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,038 $0 Implemented
MA0535 # 13 Y:2003 13 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $617 $0 Implemented
MA0520 # 01 Y:2002 01 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,609 $0 Not Implemented
MA0520 # 02 Y:2002 02 2002 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $2,161 $2,000 Implemented
MA0520 # 03 Y:2002 03 2002 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,389 $500 Implemented
MA0520 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $627 $4,496 Not Implemented