Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,692
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0557 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $470 | $1,340 | Implemented |
MA0556 # 01 Y:2004 | 01 | 2004 | IMPROVE SPACE COMFORT CONDITIONING | $17,360 | $17,910 | Not Implemented |
MA0556 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $13,042 | $6,750 | Implemented |
MA0556 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,720 | $10,350 | Implemented |
MA0556 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,840 | $2,131 | Implemented |
MA0556 # 05 Y:2004 | 05 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,167 | $10,200 | Implemented |
MA0556 # 06 Y:2004 | 06 | 2004 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $5,923 | $12,926 | Not Implemented |
MA0556 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,534 | $529 | Implemented |
MA0554 # 01 Y:2004 | 01 | 2004 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $872,428 | $2,632,200 | n/a |
MA0554 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $119,550 | $175,000 | Not Implemented |
MA0554 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $48,636 | $76,341 | Not Implemented |
MA0554 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,697 | $11,100 | Not Implemented |
MA0554 # 05 Y:2004 | 05 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $6,330 | $8,961 | Implemented |
MA0554 # 06 Y:2004 | 06 | 2004 | INSULATE FEEDWATER TANK | $1,784 | $1,300 | Implemented |
MA0555 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $212,625 | $986,100 | Implemented |
MA0555 # 02 Y:2004 | 02 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,690 | $81,637 | Implemented |
MA0555 # 03 Y:2004 | 03 | 2004 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,915 | $44,790 | Implemented |
MA0555 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,282 | $5,430 | Implemented |
MA0555 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,840 | $500 | Implemented |
MA0555 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,791 | $4,850 | Implemented |
MA0555 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $1,836 | $768 | Implemented |
MA0555 # 08 Y:2004 | 08 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $1,139 | $650 | Implemented |
MA0555 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $535 | $180 | Implemented |
MA0553 # 01 Y:2004 | 01 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $41,580 | $20,000 | Not Implemented |
MA0553 # 02 Y:2004 | 02 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,555 | $15,605 | Implemented |