Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0240 # 04 Y:2002 | 04 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $132 | $60 | Implemented |
NC0240 # 05 Y:2002 | 05 | 2002 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $3,000 | $1,000 | Implemented |
NC0240 # 06 Y:2002 | 06 | 2002 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $100,000 | $200,000 | Implemented |
NC0239 # 01 Y:2002 | 01 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,731 | $15,000 | Not Implemented |
NC0239 # 02 Y:2002 | 02 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $614 | $3,190 | Implemented |
NC0239 # 03 Y:2002 | 03 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $132 | $60 | Implemented |
NC0239 # 04 Y:2002 | 04 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,119 | $15,000 | Not Implemented |
NC0239 # 05 Y:2002 | 05 | 2002 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $11,025 | $6,500 | Not Implemented |
NC0235 # 01 Y:2002 | 01 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $17,277 | $100 | Implemented |
NC0235 # 02 Y:2002 | 02 | 2002 | INSTALL BACK-UP EQUIPMENT | $156,500 | $1,000 | Not Implemented |
NC0235 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $12,464 | $550 | Not Implemented |
NC0235 # 04 Y:2002 | 04 | 2002 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $30,410 | $1,000 | Implemented |
NC0235 # 05 Y:2002 | 05 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $23,267 | $15,570 | Implemented |
NC0235 # 06 Y:2002 | 06 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,171 | $2,434 | Implemented |
NC0235 # 07 Y:2002 | 07 | 2002 | RECOVER AND REUSE COOLING WATER | $213 | $500 | Not Implemented |
NC0232 # 01 Y:2002 | 01 | 2002 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $13,002 | $800 | Implemented |
NC0232 # 02 Y:2002 | 02 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,335 | $15,000 | Not Implemented |
NC0232 # 03 Y:2002 | 03 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $1,645 | $1,818 | Implemented |
NC0232 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $561 | $248 | Implemented |
NC0232 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $740 | $150 | Implemented |
NC0232 # 06 Y:2002 | 06 | 2002 | KEEP BOILER TUBES CLEAN | $596 | $1,100 | Not Implemented |
NC0232 # 07 Y:2002 | 07 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,486 | $850 | Implemented |
NC0231 # 01 Y:2002 | 01 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $2,088 | $2,383 | Not Implemented |
NC0231 # 02 Y:2002 | 02 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $324 | $736 | Not Implemented |
NC0231 # 03 Y:2002 | 03 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,818 | $830 | Not Implemented |