IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,985

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0063 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $776 $480 Implemented
NC0063 # 02 Y:1995 02 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $740 $95 Implemented
NC0063 # 03 Y:1995 03 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $446 $600 Not Implemented
NC0063 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,719 $5,310 Implemented
NC0063 # 05 Y:1995 05 1995 CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES $93,750 $100,000 Implemented
NC0063 # 06 Y:1995 06 1995 IMPROVE COMBUSTION CONTROL CAPABILITY $40,500 $35,000 Implemented
NC0060 # 01 Y:1995 01 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $1,626 $0 Implemented
NC0060 # 02 Y:1995 02 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,215 $19,196 Not Implemented
NC0060 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $354 $2,430 Not Implemented
NC0060 # 04 Y:1995 04 1995 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $4,567 $15,000 Not Implemented
NC0060 # 05 Y:1995 05 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,838 $15,000 Not Implemented
NC0060 # 06 Y:1995 06 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $2,634 $4,545 Implemented
NC0060 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $463 $1,556 Implemented
NC0060 # 08 Y:1995 08 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,418 $1,500 Implemented
NC0059 # 01 Y:1995 01 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,340 $0 Implemented
NC0059 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $802 $450 Implemented
NC0059 # 03 Y:1995 03 1995 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $95,329 $560,000 Not Implemented
NC0059 # 04 Y:1995 04 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $14,062 $1,540 Implemented
NC0059 # 05 Y:1995 05 1995 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $6,149 $7,500 Not Implemented
NC0059 # 06 Y:1995 06 1995 RECOVER AND REUSE COOLING WATER $27,000 $6,000 Not Implemented
NC0059 # 07 Y:1995 07 1995 RECOVER AND REUSE WASTE MATERIAL $40,000 $0 Implemented
NC0058 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $149 $292 Implemented
NC0058 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $16,902 $30,410 Implemented
NC0058 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,940 $10,000 Not Implemented
NC0058 # 04 Y:1995 04 1995 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $19,158 $80,000 Not Implemented