Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0126 # 05 Y:1997 | 05 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,042 | $5,200 | Implemented |
NC0126 # 06 Y:1997 | 06 | 1997 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $33,895 | $56,800 | Not Implemented |
NC0126 # 07 Y:1997 | 07 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $66,010 | $220,000 | Not Implemented |
NC0126 # 08 Y:1997 | 08 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $962 | $2,400 | Not Implemented |
NC0126 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $888 | $1,314 | Implemented |
NC0126 # 10 Y:1997 | 10 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,268 | $9,150 | Not Implemented |
NC0126 # 11 Y:1997 | 11 | 1997 | ADD AREA LIGHTING SWITCHES | $3,197 | $2,420 | Not Implemented |
NC0126 # 12 Y:1997 | 12 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143 | $180 | Implemented |
NC0126 # 13 Y:1997 | 13 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $322 | $240 | Not Implemented |
NC0122 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $1,591 | $647 | Not Implemented |
NC0122 # 02 Y:1997 | 02 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $884 | $468 | Not Implemented |
NC0122 # 03 Y:1997 | 03 | 1997 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $831 | $1,000 | Not Implemented |
NC0122 # 04 Y:1997 | 04 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,262 | $600 | Not Implemented |
NC0122 # 05 Y:1997 | 05 | 1997 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,108 | $3,500 | Not Implemented |
NC0122 # 06 Y:1997 | 06 | 1997 | REPLACE BOILER | $8,881 | $36,000 | Not Implemented |
NC0122 # 07 Y:1997 | 07 | 1997 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $973 | $1,500 | Implemented |
NC0122 # 08 Y:1997 | 08 | 1997 | TREAT AND REUSE RINSE WATERS | $12,101 | $2,500 | Not Implemented |
NC0122 # 09 Y:1997 | 09 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $27,463 | $13,500 | Not Implemented |
NC0122 # 10 Y:1997 | 10 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,157 | $400 | Implemented |
NC0122 # 11 Y:1997 | 11 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $36,445 | $100,000 | Not Implemented |
NC0122 # 12 Y:1997 | 12 | 1997 | EXPAND OPERATIONS INTO UNUSED SPACE | $9,330 | $3,330 | Implemented |
NC0117 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $271 | $499 | Implemented |
NC0117 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $100 | $111 | Implemented |
NC0117 # 03 Y:1997 | 03 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $791 | $140 | Implemented |
NC0117 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $22 | $48 | Implemented |