Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,985

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0539 # 04 Y:2015 04 2015 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,453 $500 Not Implemented
NC0539 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,189 $3,822 Not Implemented
NC0539 # 06 Y:2015 06 2015 REPAIR AND ELIMINATE STEAM LEAKS $1,216 $2,500 Implemented
NC0539 # 07 Y:2015 07 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $357 $100 Implemented
NC0539 # 08 Y:2015 08 2015 INSTALL OCCUPANCY SENSORS $53 $200 Not Implemented
NC0538 # 01 Y:2015 01 2015 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,825 $50,000 Not Implemented
NC0538 # 02 Y:2015 02 2015 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,806 $21,000 Not Implemented
NC0538 # 03 Y:2015 03 2015 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,306 $1,700 Not Implemented
NC0538 # 04 Y:2015 04 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,255 $20,000 Not Implemented
NC0538 # 05 Y:2015 05 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $828 $100 Implemented
NC0538 # 06 Y:2015 06 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,230 $1,875 Not Implemented
NC0538 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $424 $1,767 Implemented
NC0538 # 08 Y:2015 08 2015 DEVELOP A REPAIR/REPLACE POLICY $1,483 $4,256 Not Implemented
NC0535 # 01 Y:2015 01 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,964 $9,077 Implemented
NC0535 # 02 Y:2015 02 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,084 $1,846 Not Implemented
NC0535 # 03 Y:2015 03 2015 INSTALL OCCUPANCY SENSORS $667 $2,297 Implemented
NC0535 # 04 Y:2015 04 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,151 $320 Not Implemented
NC0535 # 05 Y:2015 05 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $214 $188 Not Implemented
NC0535 # 06 Y:2015 06 2015 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $917 $200 Not Implemented
NC0535 # 07 Y:2015 07 2015 DEVELOP A REPAIR/REPLACE POLICY $1,766 $8,146 Not Implemented
NC0535 # 08 Y:2015 08 2015 RECOVER WASTE HEAT FROM EQUIPMENT $1,917 $100 Implemented
NC0535 # 09 Y:2015 09 2015 RECOVER WASTE HEAT FROM EQUIPMENT $1,975 $1,750 Implemented
NC0535 # 10 Y:2015 10 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $598 $100 Implemented
NC0535 # 11 Y:2015 11 2015 RECOVER WASTE HEAT FROM EQUIPMENT $2,512 $8,000 Not Implemented
NC0535 # 12 Y:2015 12 2015 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $161 $100 Not Implemented