Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0560 # 06 Y:2016 | 06 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,027 | $500 | Not Implemented |
NC0560 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,287 | $100 | Not Implemented |
NC0560 # 08 Y:2016 | 08 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,436 | $6,000 | Not Implemented |
NC0560 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $812 | $300 | Not Implemented |
NC0560 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $519 | $521 | Implemented |
NC0560 # 11 Y:2016 | 11 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $474 | $455 | Implemented |
NC0560 # 12 Y:2016 | 12 | 2016 | USE PHOTOCELL CONTROLS | $194 | $250 | Implemented |
NC0560 # 13 Y:2016 | 13 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,597 | $500 | Implemented |
NC0560 # 14 Y:2016 | 14 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,514 | $5,865 | Implemented |
NC0560 # 15 Y:2016 | 15 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,030 | $200 | Not Implemented |
NC0559 # 01 Y:2016 | 01 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $109,787 | $1,000 | Implemented |
NC0559 # 02 Y:2016 | 02 | 2016 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $28,202 | $75,000 | Not Implemented |
NC0559 # 03 Y:2016 | 03 | 2016 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $4,003 | $1,000 | Implemented |
NC0559 # 04 Y:2016 | 04 | 2016 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,720 | $10,000 | Not Implemented |
NC0559 # 05 Y:2016 | 05 | 2016 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $20,410 | $15,050 | Not Implemented |
NC0559 # 06 Y:2016 | 06 | 2016 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,950 | $25,000 | Implemented |
NC0559 # 07 Y:2016 | 07 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $34,146 | $10,000 | Implemented |
NC0559 # 08 Y:2016 | 08 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $7,231 | $2,000 | Implemented |
NC0559 # 09 Y:2016 | 09 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,038 | $320 | Implemented |
NC0559 # 10 Y:2016 | 10 | 2016 | USE PHOTOCELL CONTROLS | $1,339 | $1,600 | Implemented |
NC0559 # 11 Y:2016 | 11 | 2016 | INSTALL OCCUPANCY SENSORS | $494 | $347 | Implemented |
NC0559 # 12 Y:2016 | 12 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,545 | $8,000 | Not Implemented |
NC0559 # 13 Y:2016 | 13 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,085 | $1,000 | Implemented |
NC0559 # 14 Y:2016 | 14 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,366 | $1,800 | Not Implemented |
NC0559 # 15 Y:2016 | 15 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,264 | $4,256 | Implemented |