Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0478 # 09 Y:2013 | 09 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $4,732 | $10,912 | Implemented |
NC0480 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $481 | $1,490 | Implemented |
NC0480 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,008 | $4,271 | Implemented |
NC0480 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $297 | $264 | Implemented |
NC0480 # 04 Y:2013 | 04 | 2013 | USE PHOTOCELL CONTROLS | $1,282 | $1,250 | Implemented |
NC0480 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,460 | $100 | Implemented |
NC0480 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $6,224 | $13,210 | Implemented |
NC0480 # 07 Y:2013 | 07 | 2013 | USE PHOTOCELL CONTROLS | $4,207 | $15,472 | Not Implemented |
NC0482 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,366 | $33,811 | Implemented |
NC0482 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76,174 | $132,415 | Not Implemented |
NC0482 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $5,539 | $2,682 | Not Implemented |
NC0482 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,981 | $2,248 | Not Implemented |
NC0482 # 05 Y:2013 | 05 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $139,540 | $300,000 | Not Implemented |
NC0482 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,303 | $4,000 | Not Implemented |
NC0482 # 07 Y:2013 | 07 | 2013 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $14,522 | $24,104 | Not Implemented |
NC0482 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,890 | $100 | Implemented |
NC0481 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,338 | $100 | Implemented |
NC0481 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,603 | $1,200 | Not Implemented |
NC0481 # 03 Y:2013 | 03 | 2013 | INSTALL COMMON HEADER ON COMPRESSORS | $2,363 | $7,500 | Implemented |
NC0481 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,333 | $3,110 | Implemented |
NC0481 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,229 | $4,819 | Not Implemented |
NC0481 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $865 | $955 | Not Implemented |
NC0481 # 07 Y:2013 | 07 | 2013 | INSTALL OCCUPANCY SENSORS | $602 | $750 | Implemented |
NC0483 # 01 Y:2013 | 01 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $240,743 | $750,000 | Not Implemented |
NC0483 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,552 | $69,000 | Not Implemented |