IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

636

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0270 # 12 Y:1997 12 1997 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $109 $0 Not Implemented
ND0268 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $29,189 $25,928 n/a
ND0268 # 02 Y:1997 02 1997 OPTIMIZE PLANT POWER FACTOR $79,500 $98,000 n/a
ND0268 # 03 Y:1997 03 1997 $27,729 $25,000 n/a
ND0268 # 04 Y:1997 04 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,416 $3,000 n/a
ND0268 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,168 $3,240 n/a
ND0268 # 06 Y:1997 06 1997 RECOVER AND REUSE WASTE MATERIAL $4,500 $4,375 n/a
ND0268 # 07 Y:1997 07 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $4,126 $6,156 n/a
ND0268 # 08 Y:1997 08 1997 INSTALL OCCUPANCY SENSORS $972 $6,400 n/a
ND0268 # 09 Y:1997 09 1997 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $823 $735 n/a
ND0268 # 10 Y:1997 10 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $495 $260 n/a
ND0268 # 11 Y:1997 11 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $296 $133 n/a
ND0268 # 12 Y:1997 12 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $300 $117 n/a
ND0260 # 01 Y:1996 01 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $880 $260 n/a
ND0260 # 02 Y:1996 02 1996 INSTALL OCCUPANCY SENSORS $719 $400 n/a
ND0260 # 03 Y:1996 03 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $203 $504 n/a
ND0260 # 04 Y:1996 04 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $153 $40 n/a
ND0260 # 05 Y:1996 05 1996 USE PHOTOCELL CONTROLS $275 $600 n/a
ND0260 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,362 $1,282 n/a
ND0260 # 07 Y:1996 07 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,431 $460 n/a
ND0260 # 08 Y:1996 08 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,635 $1,000 n/a
ND0260 # 09 Y:1996 09 1996 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $29,520 $100,000 n/a
ND0260 # 10 Y:1996 10 1996 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $781 $1,156 n/a
ND0260 # 11 Y:1996 11 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $3,223 $200 n/a
ND0257 # 01 Y:1996 01 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $68 $200 Not Implemented