Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ST0080 # 07 Y:1986 | 07 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,682 | $6,000 | Not Implemented |
ST0074 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,553 | $0 | Implemented |
ST0074 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,364 | $6,000 | Not Implemented |
ST0074 # 03 Y:1986 | 03 | 1986 | USE OPTIMUM THICKNESS INSULATION | $1,489 | $1,500 | Implemented |
ST0074 # 04 Y:1986 | 04 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,008 | $3,000 | Not Implemented |
ST0074 # 05 Y:1986 | 05 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,074 | $1,050 | Not Implemented |
ST0074 # 06 Y:1986 | 06 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $125,108 | $160,000 | Implemented |
ST0075 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,355 | $0 | Implemented |
ST0075 # 02 Y:1986 | 02 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $130 | $400 | Implemented |
ST0075 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,137 | $537 | Implemented |
ST0075 # 04 Y:1986 | 04 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $78,667 | $20,000 | Not Implemented |
ST0075 # 05 Y:1986 | 05 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,765 | $3,667 | Not Implemented |
ST0075 # 06 Y:1986 | 06 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $1,976 | $600 | Not Implemented |
ST0075 # 07 Y:1986 | 07 | 1986 | REPAIR OR REPLACE STEAM TRAPS | $6,449 | $500 | Implemented |
ST0075 # 08 Y:1986 | 08 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,136 | $507 | Implemented |
ST0076 # 01 Y:1986 | 01 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $47,801 | $60,000 | Implemented |
ST0076 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,121 | $500 | Implemented |
ST0076 # 03 Y:1986 | 03 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $930 | $0 | Not Implemented |
ST0076 # 04 Y:1986 | 04 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,072 | $3,540 | Implemented |
ST0076 # 05 Y:1986 | 05 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,494 | $70 | Implemented |
ST0077 # 09 Y:1986 | 09 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $735 | $278 | Implemented |
ST0080 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,482 | $7,000 | Implemented |
ST0080 # 01 Y:1986 | 01 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,901 | $59,000 | Not Implemented |
ST0080 # 03 Y:1986 | 03 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,370 | $0 | Implemented |
ST0077 # 08 Y:1986 | 08 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $169 | $150 | Implemented |