IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,950

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0453 # 01 Y:1992 01 1992 RECOVER WASTE HEAT FROM EQUIPMENT $5,100 $2,055 Not Implemented
TN0453 # 02 Y:1992 02 1992 KEEP LAMPS AND REFLECTORS CLEAN $14,854 $39,353 Not Implemented
TN0453 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $11,778 $7,975 Not Implemented
TN0453 # 04 Y:1992 04 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,098 $16,000 Not Implemented
TN0461 # 01 Y:1992 01 1992 KEEP LAMPS AND REFLECTORS CLEAN $41,641 $47,895 Not Implemented
TN0461 # 02 Y:1992 02 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,756 $1,000 Not Implemented
TN0461 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $9,074 $1,380 Not Implemented
TN0461 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,188 $2,188 Not Implemented
TN0461 # 05 Y:1992 05 1992 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,758 $1,535 Not Implemented
TN0461 # 06 Y:1992 06 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,178 $0 Not Implemented
TN0461 # 07 Y:1992 07 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $598 $480 Not Implemented
TN0461 # 08 Y:1992 08 1992 OPTIMIZE PLANT POWER FACTOR $29,700 $32,400 Not Implemented
TN0461 # 09 Y:1992 09 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $14,582 $0 Not Implemented
TN0454 # 01 Y:1992 01 1992 INCREASE AMOUNT OF CONDENSATE RETURNED $12,838 $10,750 Implemented
TN0454 # 02 Y:1992 02 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,912 $1,000 Implemented
TN0454 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,682 $1,000 Implemented
TN0454 # 04 Y:1992 04 1992 KEEP LAMPS AND REFLECTORS CLEAN $2,438 $5,145 Implemented
TN0454 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,082 $1,315 Implemented
TN0454 # 06 Y:1992 06 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $792 $1,315 Implemented
TN0454 # 07 Y:1992 07 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,210 $0 Implemented
TN0455 # 01 Y:1992 01 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $12,170 $6,525 Implemented
TN0455 # 02 Y:1992 02 1992 KEEP LAMPS AND REFLECTORS CLEAN $12,358 $14,750 Implemented
TN0455 # 03 Y:1992 03 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,644 $0 Implemented
TN0455 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,871 $587 Implemented
TN0455 # 05 Y:1992 05 1992 IMPROVE LUBRICATION PRACTICES $621 $80 Implemented