Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
128
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0146 # 02 Y:2014 | 02 | 2014 | INSTALL SKYLIGHTS | $2,012 | $14,000 | Not Implemented |
TT0142 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,651 | $3,000 | Implemented |
TT0142 # 02 Y:2014 | 02 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $299 | $596 | Not Implemented |
TT0142 # 06 Y:2014 | 06 | 2014 | USE PHOTOCELL CONTROLS | $49 | $45 | Implemented |
TT0142 # 05 Y:2014 | 05 | 2014 | DISCONNECT BALLASTS | $555 | $60 | Not Implemented |
TT0146 # 01 Y:2014 | 01 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $1,943 | $822 | Implemented |
TT0146 # 03 Y:2014 | 03 | 2014 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,898 | $24,450 | Not Implemented |
TT0142 # 03 Y:2014 | 03 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $861 | $1,662 | Not Implemented |
TT0146 # 04 Y:2014 | 04 | 2014 | BURN WASTE PAPER FOR HEAT | $5,426 | $19,895 | Not Implemented |
TT0142 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,305 | $1,400 | Implemented |
TT0144 # 16 Y:2014 | 16 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $18,840 | $25,000 | Not Implemented |
TT0144 # 15 Y:2014 | 15 | 2014 | INSTALL OCCUPANCY SENSORS | $3,094 | $1,691 | Not Implemented |
TT0144 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,639 | $4,000 | Implemented |
TT0144 # 01 Y:2014 | 01 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $14,166 | $5,000 | Implemented |
TT0144 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,695 | $30,000 | Not Implemented |
TT0144 # 09 Y:2014 | 09 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,030 | $30,000 | Not Implemented |
TT0144 # 13 Y:2014 | 13 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,928 | $30,000 | Not Implemented |
TT0144 # 11 Y:2014 | 11 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,435 | $25,000 | Not Implemented |
TT0144 # 12 Y:2014 | 12 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,105 | $25,000 | Not Implemented |
TT0144 # 14 Y:2014 | 14 | 2014 | USE PHOTOCELL CONTROLS | $49,879 | $7,350 | Not Implemented |
TT0144 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,000 | $10,000 | Not Implemented |
TT0144 # 10 Y:2014 | 10 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,775 | $30,000 | Not Implemented |
TT0144 # 08 Y:2014 | 08 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,212 | $30,000 | Not Implemented |
TT0144 # 02 Y:2014 | 02 | 2014 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $26,051 | $22,000 | Implemented |
TT0144 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,000 | $20,000 | Not Implemented |