Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
74
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0390 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $760 | $2,000 | Implemented |
UD0388 # 01 Y:1992 | 01 | 1992 | ISOLATE HOT OR COLD EQUIPMENT | $7,341 | $0 | Implemented |
UD0389 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,929 | $6,000 | Implemented |
UD0389 # 02 Y:1992 | 02 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $643 | $50 | Implemented |
UD0389 # 01 Y:1992 | 01 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,419 | $0 | Implemented |
UD0388 # 03 Y:1992 | 03 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,341 | $800 | Implemented |
UD0390 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $2,033 | $300 | Implemented |
UD0384 # 03 Y:1992 | 03 | 1992 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $11,343 | $3,000 | Implemented |
UD0385 # 05 Y:1992 | 05 | 1992 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $12,716 | $3,428 | Implemented |
UD0383 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,329 | $13,345 | Implemented |
UD0383 # 04 Y:1992 | 04 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,389 | $400 | Implemented |
UD0383 # 02 Y:1992 | 02 | 1992 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $8,673 | $2,000 | Implemented |
UD0383 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,953 | $500 | Implemented |
UD0382 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,352 | $4,895 | Implemented |
UD0385 # 06 Y:1992 | 06 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,807 | $2,200 | Implemented |
UD0387 # 01 Y:1992 | 01 | 1992 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $23,256 | $55,000 | Implemented |
UD0386 # 03 Y:1992 | 03 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $4,645 | $-3,720 | Implemented |
UD0387 # 07 Y:1992 | 07 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,594 | $1,000 | Implemented |
UD0386 # 04 Y:1992 | 04 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $539 | $900 | Implemented |
UD0387 # 02 Y:1992 | 02 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,120 | $38,000 | Implemented |
UD0385 # 01 Y:1992 | 01 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,747 | $60,000 | Implemented |
UD0387 # 05 Y:1992 | 05 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,875 | $2,000 | Implemented |
UD0386 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $1,425 | $600 | Implemented |
UD0385 # 04 Y:1992 | 04 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,026 | $3,294 | Implemented |
UD0387 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,668 | $0 | Implemented |