IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

28

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0235 # 02 Y:1999 02 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $5,509 $2,875 Implemented
UL0235 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $18,187 $21,040 Not Implemented
UL0228 # 06 Y:1999 06 1999 $250,000 $0 Not Implemented
UL0228 # 05 Y:1999 05 1999 $88,740 $1,560 Not Implemented
UL0228 # 04 Y:1999 04 1999 USE LESS WASTEFUL PACKAGING $58,958 $1,000 Not Implemented
UL0228 # 03 Y:1999 03 1999 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $9,641 $10,400 Not Implemented
UL0228 # 02 Y:1999 02 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $8,550 $0 Not Implemented
UL0228 # 01 Y:1999 01 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,001 $20 Implemented
UL0223 # 05 Y:1999 05 1999 $721,820 $48,180 Not Implemented
UL0223 # 04 Y:1999 04 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,000 $8,500 Not Implemented
UL0223 # 03 Y:1999 03 1999 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $844 $930 Not Implemented
UL0223 # 02 Y:1999 02 1999 INSTALL TIMERS AND/OR THERMOSTATS $263 $0 Not Implemented
UL0223 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $710 $101 Not Implemented
UL0221 # 04 Y:1999 04 1999 $1,999,760 $1,034,600 Not Implemented
UL0221 # 05 Y:1999 05 1999 $21,950 $20,120 Not Implemented
UL0221 # 03 Y:1999 03 1999 METER WASTE WATER $1,766 $677 Not Implemented
UL0221 # 02 Y:1999 02 1999 WASH AND REUSE RAGS ON-SITE $62,626 $11,315 Not Implemented
UL0221 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $34,663 $21,006 Not Implemented
UL0219 # 06 Y:1999 06 1999 $4,514 $60 Implemented
UL0219 # 05 Y:1999 05 1999 $2,520 $300 Implemented
UL0219 # 04 Y:1999 04 1999 METER WASTE WATER $4,053 $0 Implemented
UL0219 # 03 Y:1999 03 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $191 $0 Implemented
UL0219 # 02 Y:1999 02 1999 OPTIMIZE PLANT POWER FACTOR $8,356 $24,627 Implemented
UL0219 # 01 Y:1999 01 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $563 $20 Implemented
UL0216 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,573 $13,951 Not Implemented