Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0108 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,190 | $400 | Implemented |
WI0108 # 04 Y:1991 | 04 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $487 | $250 | Implemented |
WI0108 # 05 Y:1991 | 05 | 1991 | INSTALL STORM WINDOWS AND DOORS | $758 | $2,514 | Implemented |
WI0108 # 06 Y:1991 | 06 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $53 | $190 | Implemented |
WI0108 # 07 Y:1991 | 07 | 1991 | INSULATE BARE EQUIPMENT | $271 | $117 | Implemented |
WI0105 # 01 Y:1990 | 01 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,875 | $1,250 | Implemented |
WI0105 # 02 Y:1990 | 02 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,254 | $0 | Not Implemented |
WI0105 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,146 | $432 | Implemented |
WI0105 # 04 Y:1990 | 04 | 1990 | INSTALL SET-BACK TIMERS | $1,696 | $1,400 | Implemented |
WI0105 # 05 Y:1990 | 05 | 1990 | INSTALL STORM WINDOWS AND DOORS | $2,224 | $4,448 | Not Implemented |
WI0105 # 06 Y:1990 | 06 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,016 | $600 | Implemented |
WI0105 # 07 Y:1990 | 07 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,271 | $2,032 | Not Implemented |
WI0105 # 08 Y:1990 | 08 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,002 | $500 | Implemented |
WI0105 # 09 Y:1990 | 09 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $632 | $500 | Not Implemented |
WI0105 # 10 Y:1990 | 10 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $445 | $1,000 | Not Implemented |
WI0105 # 11 Y:1990 | 11 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $213 | $0 | Implemented |
WI0101 # 01 Y:1990 | 01 | 1990 | INSTALL SET-BACK TIMERS | $4,854 | $3,134 | Not Implemented |
WI0101 # 02 Y:1990 | 02 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,727 | $0 | Not Implemented |
WI0101 # 03 Y:1990 | 03 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,265 | $2,800 | Not Implemented |
WI0101 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,566 | $2,500 | Not Implemented |
WI0101 # 05 Y:1990 | 05 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,060 | $1,000 | Not Implemented |
WI0101 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $1,046 | $1,000 | Not Implemented |
WI0101 # 07 Y:1990 | 07 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,897 | $4,000 | Not Implemented |
WI0101 # 08 Y:1990 | 08 | 1990 | INSTALL STORM WINDOWS AND DOORS | $1,666 | $3,240 | Not Implemented |
WI0101 # 09 Y:1990 | 09 | 1990 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,924 | $0 | Not Implemented |