Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0012 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,335 | $2,000 | Implemented |
WI0012 # 05 Y:1987 | 05 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,508 | $5,000 | Not Implemented |
WI0013 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $1,120 | $0 | Not Implemented |
WI0013 # 02 Y:1987 | 02 | 1987 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $302 | $0 | Implemented |
WI0013 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,253 | $4,328 | Implemented |
WI0013 # 04 Y:1987 | 04 | 1987 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $840 | $1,500 | Implemented |
WI0013 # 05 Y:1987 | 05 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $882 | $700 | Implemented |
WI0010 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $2,205 | $0 | Not Implemented |
WI0010 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,378 | $0 | Implemented |
WI0010 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,998 | $1,385 | Implemented |
WI0010 # 04 Y:1987 | 04 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,364 | $500 | Implemented |
WI0010 # 05 Y:1987 | 05 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,096 | $32,000 | Not Implemented |
WI0011 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $23,501 | $0 | Not Implemented |
WI0011 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,151 | $0 | Implemented |
WI0011 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,974 | $4,177 | Implemented |
WI0011 # 04 Y:1987 | 04 | 1987 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $265 | $0 | Not Implemented |
WI0011 # 05 Y:1987 | 05 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $983 | $500 | Implemented |
WI0011 # 06 Y:1987 | 06 | 1987 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,909 | $750 | Not Implemented |
WI0008 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $562 | $0 | Not Implemented |
WI0008 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $269 | $0 | Implemented |
WI0008 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $644 | $701 | Implemented |
WI0008 # 04 Y:1987 | 04 | 1987 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $122 | $0 | Implemented |
WI0008 # 05 Y:1987 | 05 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,563 | $5,000 | Not Implemented |
WI0008 # 07 Y:1987 | 07 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $695 | $500 | Implemented |
WI0009 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $15,779 | $0 | Not Implemented |