IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,332

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0408 # 13 Y:2010 13 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $415 $1,118 Not Implemented
WV0400 # 01 Y:2010 01 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $104,233 $15,269 Implemented
WV0400 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,861 $27,401 Implemented
WV0400 # 03 Y:2010 03 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $15,520 $7,000 Implemented
WV0400 # 04 Y:2010 04 2010 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $10,016 $5,000 Not Implemented
WV0400 # 05 Y:2010 05 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,436 $24,000 Not Implemented
WV0400 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,119 $10,100 Implemented
WV0400 # 07 Y:2010 07 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $7,115 $4,520 Implemented
WV0400 # 08 Y:2010 08 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,554 $3,700 Not Implemented
WV0400 # 09 Y:2010 09 2010 USE RADIANT HEATER FOR SPOT HEATING $6,252 $9,080 Not Implemented
WV0400 # 10 Y:2010 10 2010 DEVELOP A REPAIR/REPLACE POLICY $4,903 $2,278 Implemented
WV0400 # 11 Y:2010 11 2010 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $4,862 $2,300 Implemented
WV0400 # 12 Y:2010 12 2010 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,744 $2,000 Implemented
WV0400 # 13 Y:2010 13 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,843 $7,688 Implemented
WV0400 # 14 Y:2010 14 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,991 $1,713 Implemented
WV0400 # 15 Y:2010 15 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,177 $1,575 Not Implemented
WV0400 # 16 Y:2010 16 2010 IMPROVE LUBRICATION PRACTICES $2,060 $1,868 Not Implemented
WV0400 # 17 Y:2010 17 2010 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,611 $1,890 Not Implemented
WV0390 # 01 Y:2009 01 2009 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST $138,137 $122,000 Not Implemented
WV0390 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,790 $72,987 Implemented
WV0390 # 03 Y:2009 03 2009 OPTIMIZE PLANT POWER FACTOR $20,264 $4,490 Implemented
WV0390 # 04 Y:2009 04 2009 USE RADIANT HEATER FOR SPOT HEATING $20,144 $22,048 Not Implemented
WV0390 # 05 Y:2009 05 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $16,484 $11,250 Not Implemented
WV0390 # 06 Y:2009 06 2009 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $15,354 $2,490 Implemented
WV0390 # 07 Y:2009 07 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,020 $2,500 Implemented