Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
64
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0398 # 01 Y:2009 | 01 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $413,866 | $803,660 | Not Implemented |
WV0398 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,891 | $900 | Implemented |
WV0398 # 16 Y:2009 | 16 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,732 | $1,075 | Not Implemented |
WV0398 # 15 Y:2009 | 15 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,030 | $0 | Implemented |
WV0398 # 14 Y:2009 | 14 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,089 | $245 | Not Implemented |
WV0398 # 13 Y:2009 | 13 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,767 | $75 | Not Implemented |
WV0398 # 12 Y:2009 | 12 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,839 | $3,121 | Not Implemented |
WV0398 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,235 | $419 | Implemented |
WV0398 # 10 Y:2009 | 10 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,120 | $0 | Not Implemented |
WV0398 # 08 Y:2009 | 08 | 2009 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $10,882 | $1,000 | Implemented |
WV0398 # 07 Y:2009 | 07 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $11,204 | $793 | Implemented |
WV0398 # 06 Y:2009 | 06 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $11,848 | $3,759 | Not Implemented |
WV0398 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,098 | $44,783 | Not Implemented |
WV0398 # 04 Y:2009 | 04 | 2009 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $75,243 | $72,000 | Not Implemented |
WV0398 # 03 Y:2009 | 03 | 2009 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $97,378 | $120,000 | Not Implemented |
WV0398 # 02 Y:2009 | 02 | 2009 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $165,791 | $85,600 | Not Implemented |
WV0398 # 17 Y:2009 | 17 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $606 | $60 | Not Implemented |
WV0395 # 08 Y:2009 | 08 | 2009 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $18,362 | $1,925 | Implemented |
WV0395 # 01 Y:2009 | 01 | 2009 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $216,842 | $130,000 | Not Implemented |
WV0395 # 02 Y:2009 | 02 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $169,299 | $189,633 | Not Implemented |
WV0395 # 03 Y:2009 | 03 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $144,811 | $1,000 | Implemented |
WV0395 # 04 Y:2009 | 04 | 2009 | INCREASE AMOUNT OF CONDENSATE RETURNED | $114,898 | $80,000 | Not Implemented |
WV0395 # 05 Y:2009 | 05 | 2009 | USE MINIMUM STEAM OPERATING PRESSURE | $113,873 | $56,000 | Not Implemented |
WV0395 # 07 Y:2009 | 07 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $26,253 | $2,304 | Implemented |
WV0395 # 06 Y:2009 | 06 | 2009 | USE PHOTOCELL CONTROLS | $104,843 | $11,000 | Not Implemented |