Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
308
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0229 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,323 | $1,200 | Implemented |
WV0229 # 07 Y:2001 | 07 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $861 | $400 | Not Implemented |
WV0229 # 14 Y:2001 | 14 | 2001 | ADVERTISE PRODUCT OR SERVICE | $13,200 | $2,000 | Implemented |
WV0229 # 04 Y:2001 | 04 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $3,599 | $350 | Not Implemented |
WV0229 # 12 Y:2001 | 12 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $13,680 | $220 | Implemented |
WV0229 # 02 Y:2001 | 02 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $776 | $750 | Implemented |
WV0229 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $755 | $400 | Not Implemented |
WV0229 # 10 Y:2001 | 10 | 2001 | INSTALL OCCUPANCY SENSORS | $2,118 | $450 | Not Implemented |
WV0229 # 11 Y:2001 | 11 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,192 | $100 | Implemented |
WV0229 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $948 | $300 | Implemented |
WV0229 # 09 Y:2001 | 09 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,189 | $11,368 | Not Implemented |
WV0229 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,684 | $4,400 | Not Implemented |
WV0229 # 05 Y:2001 | 05 | 2001 | USE SYNTHETIC LUBRICANT | $1,215 | $450 | Implemented |
WV0229 # 13 Y:2001 | 13 | 2001 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $45,000 | $15,000 | Implemented |
WV0228 # 04 Y:2001 | 04 | 2001 | INSULATE BARE EQUIPMENT | $187 | $98 | Implemented |
WV0228 # 03 Y:2001 | 03 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,376 | $2,400 | Implemented |
WV0228 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,326 | $1,245 | Implemented |
WV0228 # 01 Y:2001 | 01 | 2001 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $221 | $130 | Not Implemented |
WV0228 # 07 Y:2001 | 07 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $147 | $320 | Not Implemented |
WV0228 # 02 Y:2001 | 02 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,117 | $720 | Implemented |
WV0228 # 12 Y:2001 | 12 | 2001 | ADJUST PH FOR NEUTRALIZATION | $11,300 | $13,000 | Not Implemented |
WV0228 # 09 Y:2001 | 09 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $18,975 | $5,660 | Not Implemented |
WV0228 # 10 Y:2001 | 10 | 2001 | BURN WASTE OIL FOR HEAT | $318 | $953 | Not Implemented |
WV0228 # 06 Y:2001 | 06 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,801 | $60 | Implemented |
WV0228 # 11 Y:2001 | 11 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $850 | $2,547 | Implemented |