Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,191
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0080 # 01 Y:1990 | 01 | 1990 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $32,758 | $0 | Implemented |
WI0080 # 04 Y:1990 | 04 | 1990 | INSTALL STORM WINDOWS AND DOORS | $1,672 | $2,640 | Implemented |
WI0080 # 05 Y:1990 | 05 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,274 | $500 | Implemented |
WI0080 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,098 | $0 | Implemented |
WI0080 # 07 Y:1990 | 07 | 1990 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $520 | $1,250 | Implemented |
WI0081 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $9,520 | $1,250 | Implemented |
WI0081 # 03 Y:1990 | 03 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,028 | $1,500 | Implemented |
WI0081 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,686 | $1,500 | Implemented |
WI0081 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,870 | $6,070 | Implemented |
WI0081 # 08 Y:1990 | 08 | 1990 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $124 | $0 | Implemented |
WI0078 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $6,074 | $500 | Implemented |
WI0078 # 02 Y:1990 | 02 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,496 | $16,000 | Implemented |
WI0078 # 03 Y:1990 | 03 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,659 | $1,500 | Implemented |
WI0078 # 06 Y:1990 | 06 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $271 | $1,000 | Implemented |
WI0078 # 07 Y:1990 | 07 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $146 | $0 | Implemented |
WI0079 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,834 | $750 | Implemented |
WI0079 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,365 | $1,000 | Implemented |
WI0079 # 04 Y:1990 | 04 | 1990 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,128 | $5,000 | Implemented |
WI0079 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $68 | $500 | Implemented |
WI0079 # 08 Y:1990 | 08 | 1990 | INSTALL STORM WINDOWS AND DOORS | $96 | $270 | Implemented |
WI0077 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,542 | $250 | Implemented |
WI0077 # 03 Y:1990 | 03 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,062 | $5,000 | Implemented |
WI0077 # 04 Y:1990 | 04 | 1990 | INSTALL STORM WINDOWS AND DOORS | $1,202 | $765 | Implemented |
WI0077 # 05 Y:1990 | 05 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,500 | $1,200 | Implemented |
WI0077 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $510 | $0 | Implemented |