Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
75,243
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0056 # 11 Y:1993 | 11 | 1993 | USE OPTIMUM THICKNESS INSULATION | $906 | $2,780 | Implemented |
IA0056 # 12 Y:1993 | 12 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $362 | $37 | Implemented |
MO0091 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,616 | $995 | Implemented |
MO0091 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,690 | $30,575 | Implemented |
AR0004 # 01 Y:1993 | 01 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $180 | $60 | Implemented |
AR0004 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,924 | $90 | Implemented |
AR0004 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,831 | $678 | Implemented |
AR0004 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,456 | $3,500 | Implemented |
UD0407 # 01 Y:1993 | 01 | 1993 | INCREASE ELECTRICAL CONDUCTOR SIZE TO REDUCE DISTRIBUTION LOSSES | $2,303 | $6,000 | Implemented |
UD0407 # 02 Y:1993 | 02 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,300 | $1,000 | Implemented |
UD0407 # 03 Y:1993 | 03 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,563 | $500 | Implemented |
UD0407 # 04 Y:1993 | 04 | 1993 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,346 | $1,500 | Implemented |
AS0089 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $969 | $475 | Implemented |
AS0089 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,082 | $1,440 | Implemented |
AS0089 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,276 | $1,520 | Implemented |
AS0089 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,153 | $653 | Implemented |
AS0089 # 07 Y:1993 | 07 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,523 | $0 | Implemented |
AS0089 # 08 Y:1993 | 08 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $309 | $400 | Implemented |
MA0279 # 01 Y:1993 | 01 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,082 | $2,800 | Implemented |
OR0179 # 01 Y:1993 | 01 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $298 | $0 | Implemented |
OR0179 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,169 | $2,274 | Implemented |
OR0179 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33 | $141 | Implemented |
OR0179 # 04 Y:1993 | 04 | 1993 | OPTIMIZE PLANT POWER FACTOR | $1,373 | $675 | Implemented |
OR0179 # 05 Y:1993 | 05 | 1993 | SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS | $3,144 | $0 | Implemented |
AS0088 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $775 | $1,485 | Implemented |