Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73,780
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0280 # 01 Y:1986 | 01 | 1986 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $3,536 | $815 | Implemented |
TN0280 # 03 Y:1986 | 03 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,837 | $10,750 | Implemented |
TN0280 # 04 Y:1986 | 04 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,539 | $2,750 | Implemented |
TN0280 # 07 Y:1986 | 07 | 1986 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $259 | $275 | Implemented |
TN0281 # 01 Y:1986 | 01 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,608 | $4,408 | Implemented |
TN0281 # 05 Y:1986 | 05 | 1986 | ADJUST VENTS TO MINIMIZE ENERGY USE | $3,340 | $0 | Implemented |
TN0281 # 07 Y:1986 | 07 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,025 | $105 | Implemented |
TN0281 # 10 Y:1986 | 10 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $93 | $0 | Implemented |
GT0286 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,600 | $16,800 | Implemented |
GT0286 # 03 Y:1986 | 03 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,375 | $5,833 | Implemented |
GT0286 # 04 Y:1986 | 04 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,190 | $1,000 | Implemented |
GT0286 # 05 Y:1986 | 05 | 1986 | IMPROVE LUBRICATION PRACTICES | $38,200 | $0 | Implemented |
GT0286 # 06 Y:1986 | 06 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $44,800 | $0 | Implemented |
GT0286 # 08 Y:1986 | 08 | 1986 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $16,626 | $5,000 | Implemented |
GT0287 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $426 | $608 | Implemented |
GT0287 # 02 Y:1986 | 02 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,279 | $5,745 | Implemented |
GT0287 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,719 | $1,000 | Implemented |
GT0287 # 05 Y:1986 | 05 | 1986 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $2,720 | $500 | Implemented |
GT0287 # 06 Y:1986 | 06 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $14,400 | $10,000 | Implemented |
GT0287 # 08 Y:1986 | 08 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,456 | $35,000 | Implemented |
GT0288 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,924 | $28,900 | Implemented |
GT0288 # 02 Y:1986 | 02 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,548 | $4,285 | Implemented |
GT0288 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,000 | $1,000 | Implemented |
GT0288 # 04 Y:1986 | 04 | 1986 | REDESIGN PROCESS | $64,500 | $114,000 | Implemented |
GT0288 # 06 Y:1986 | 06 | 1986 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $13,970 | $20,000 | Implemented |