Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73,765
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0136 # 21 Y:1984 | 21 | 1984 | IMPROVE LUBRICATION PRACTICES | $2,590 | $2,550 | Implemented |
KU0136 # 23 Y:1984 | 23 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $795 | $0 | Implemented |
KU0137 # 02 Y:1984 | 02 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $3,839 | $0 | Implemented |
KU0137 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,930 | $0 | Implemented |
KU0137 # 12 Y:1984 | 12 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $235 | $50 | Implemented |
KU0137 # 14 Y:1984 | 14 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $118 | $0 | Implemented |
KU0138 # 01 Y:1984 | 01 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,748 | $0 | Implemented |
KU0138 # 02 Y:1984 | 02 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $177 | $250 | Implemented |
KU0138 # 03 Y:1984 | 03 | 1984 | INSTALL SET-BACK TIMERS | $1,100 | $0 | Implemented |
KU0138 # 04 Y:1984 | 04 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,807 | $200 | Implemented |
KU0138 # 11 Y:1984 | 11 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $661 | $0 | Implemented |
KU0138 # 12 Y:1984 | 12 | 1984 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $884 | $120 | Implemented |
KU0131 # 03 Y:1984 | 03 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,281 | $200 | Implemented |
KU0131 # 05 Y:1984 | 05 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,310 | $170 | Implemented |
KU0131 # 07 Y:1984 | 07 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $485 | $350 | Implemented |
KU0131 # 13 Y:1984 | 13 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $396 | $0 | Implemented |
KU0131 # 14 Y:1984 | 14 | 1984 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $330 | $0 | Implemented |
KU0131 # 16 Y:1984 | 16 | 1984 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $136 | $0 | Implemented |
KU0131 # 19 Y:1984 | 19 | 1984 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $113 | $39 | Implemented |
KU0132 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,142 | $6,807 | Implemented |
KU0132 # 02 Y:1984 | 02 | 1984 | IMPROVE LUBRICATION PRACTICES | $3,765 | $800 | Implemented |
KU0132 # 03 Y:1984 | 03 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,978 | $3,155 | Implemented |
KU0132 # 05 Y:1984 | 05 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $903 | $0 | Implemented |
KU0132 # 08 Y:1984 | 08 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,443 | $85 | Implemented |
KU0132 # 09 Y:1984 | 09 | 1984 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,418 | $1,110 | Implemented |