Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73,765
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0209 # 08 Y:1984 | 08 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,672 | $5,000 | Implemented |
KU0112 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $18,588 | $1,074 | Implemented |
KU0112 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $795 | $200 | Implemented |
KU0112 # 05 Y:1984 | 05 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $398 | $400 | Implemented |
KU0112 # 06 Y:1984 | 06 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,012 | $2,800 | Implemented |
KU0112 # 08 Y:1984 | 08 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $286 | $0 | Implemented |
KU0113 # 03 Y:1984 | 03 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $523 | $1,010 | Implemented |
KU0113 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $431 | $200 | Implemented |
KU0113 # 05 Y:1984 | 05 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $120 | $160 | Implemented |
TN0198 # 01 Y:1984 | 01 | 1984 | INSULATE BARE EQUIPMENT | $3,850 | $2,583 | Implemented |
TN0198 # 02 Y:1984 | 02 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $442 | $589 | Implemented |
TN0198 # 03 Y:1984 | 03 | 1984 | USE MINIMUM STEAM OPERATING PRESSURE | $257 | $0 | Implemented |
TN0198 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $0 | $108 | Implemented |
TN0198 # 05 Y:1984 | 05 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $168 | $183 | Implemented |
TN0199 # 01 Y:1984 | 01 | 1984 | HEAT WATER WITH EXHAUST HEAT | $3,718 | $10,800 | Implemented |
TN0199 # 02 Y:1984 | 02 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $1,733 | $0 | Implemented |
TN0199 # 03 Y:1984 | 03 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $5,890 | $800 | Implemented |
OK0113 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $198 | $235 | Implemented |
OK0114 # 01 Y:1984 | 01 | 1984 | OPTIMIZE PLANT POWER FACTOR | $12,995 | $27,645 | Implemented |
OK0114 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,226 | $18,444 | Implemented |
OK0114 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $404 | $79 | Implemented |
OK0114 # 07 Y:1984 | 07 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $135 | $185 | Implemented |
OK0115 # 01 Y:1984 | 01 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $614 | $450 | Implemented |
OK0115 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,540 | $450 | Implemented |
OK0115 # 03 Y:1984 | 03 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $1,020 | $600 | Implemented |