Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
142
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0302 # 06 Y:1994 | 06 | 1994 | INSTALL OCCUPANCY SENSORS | $1,995 | $1,466 | Implemented |
MA0302 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,628 | $6,425 | Implemented |
MA0258 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $590 | $1 | Implemented |
MA0258 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $177 | $145 | Implemented |
MA0233 # 01 Y:1992 | 01 | 1992 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $28,770 | $2,000 | Implemented |
MA0233 # 03 Y:1992 | 03 | 1992 | INSULATE BARE EQUIPMENT | $10,672 | $12,412 | Implemented |
MA0233 # 04 Y:1992 | 04 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,341 | $14,210 | Implemented |
MA0233 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,334 | $8,000 | Implemented |
MA0233 # 07 Y:1992 | 07 | 1992 | IMPROVE LUBRICATION PRACTICES | $1,170 | $0 | Implemented |
MA0218 # 01 Y:1991 | 01 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,047 | $51,400 | Implemented |
MA0218 # 02 Y:1991 | 02 | 1991 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,649 | $15,470 | Implemented |
MA0218 # 03 Y:1991 | 03 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,973 | $724 | Implemented |
MA0218 # 04 Y:1991 | 04 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,981 | $726 | Implemented |
MA0218 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $753 | $0 | Implemented |
MA0218 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,262 | $15,300 | Implemented |
MA0210 # 01 Y:1991 | 01 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $300 | $136 | Implemented |
MA0210 # 02 Y:1991 | 02 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $191 | $350 | Implemented |
MA0210 # 03 Y:1991 | 03 | 1991 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $651 | $2,764 | Implemented |
MA0210 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $136 | $47 | Implemented |
MA0210 # 05 Y:1991 | 05 | 1991 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $151 | $405 | Implemented |
MA0210 # 06 Y:1991 | 06 | 1991 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $1,286 | $2,375 | Implemented |
MA0180 # 01 Y:1990 | 01 | 1990 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,523 | $5,750 | Implemented |
MA0180 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,604 | $334 | Implemented |
MA0161 # 01 Y:1989 | 01 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $335 | $703 | Implemented |
MA0131 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $749 | $1,042 | Implemented |