Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,184
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0114 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,021 | $1,150 | Implemented |
AT0114 # 06 Y:1988 | 06 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,069 | $0 | Implemented |
AT0114 # 08 Y:1988 | 08 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,877 | $1,019 | Implemented |
AT0114 # 09 Y:1988 | 09 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $48,730 | $3,360 | Implemented |
AT0110 # 01 Y:1988 | 01 | 1988 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $18,131 | $5,540 | Implemented |
AT0110 # 02 Y:1988 | 02 | 1988 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $25,785 | $5,000 | Implemented |
AT0110 # 03 Y:1988 | 03 | 1988 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,765 | $3,500 | Implemented |
AT0110 # 05 Y:1988 | 05 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $21,453 | $21,000 | Implemented |
AT0110 # 07 Y:1988 | 07 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $32,558 | $5,000 | Implemented |
AT0110 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $378 | $331 | Implemented |
AT0110 # 09 Y:1988 | 09 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $705 | $1,500 | Implemented |
AT0110 # 11 Y:1988 | 11 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $622 | $0 | Implemented |
AT0107 # 01 Y:1988 | 01 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $43,172 | $0 | Implemented |
AT0107 # 03 Y:1988 | 03 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $406 | $0 | Implemented |
AT0107 # 04 Y:1988 | 04 | 1988 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $139 | $0 | Implemented |
AT0107 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $531 | $490 | Implemented |
AT0107 # 06 Y:1988 | 06 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,249 | $1,400 | Implemented |
AT0107 # 07 Y:1988 | 07 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,436 | $0 | Implemented |
AT0107 # 08 Y:1988 | 08 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $789 | $1,000 | Implemented |
AT0107 # 09 Y:1988 | 09 | 1988 | IMPROVE LUBRICATION PRACTICES | $586 | $0 | Implemented |
AT0107 # 10 Y:1988 | 10 | 1988 | INSULATE BARE EQUIPMENT | $664 | $500 | Implemented |
AT0107 # 12 Y:1988 | 12 | 1988 | REDUCE VENTILATION AIR | $512 | $300 | Implemented |
AT0108 # 01 Y:1988 | 01 | 1988 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $41,053 | $11,000 | Implemented |
AT0108 # 02 Y:1988 | 02 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,433 | $5,310 | Implemented |
AT0108 # 03 Y:1988 | 03 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,258 | $4,500 | Implemented |