Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,265
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0522 # 01 Y:2007 | 01 | 2007 | INCREASE USE OF AUTOMATION | $4,990 | $0 | Implemented |
AM0522 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,600 | $250 | Implemented |
AM0522 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $810 | $245 | Implemented |
AM0521 # 01 Y:2007 | 01 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $183,000 | $1,635 | Implemented |
AM0521 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,670 | $20,000 | Implemented |
AM0521 # 04 Y:2007 | 04 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,340 | $8,050 | Implemented |
AM0521 # 08 Y:2007 | 08 | 2007 | PAY UTILITY BILLS ON TIME | $2,066 | $0 | Implemented |
AM0520 # 01 Y:2007 | 01 | 2007 | REDUCE SCRAP PRODUCTION | $240,000 | $380,000 | Implemented |
AM0520 # 02 Y:2007 | 02 | 2007 | RECOVER AND REUSE COOLING WATER | $77,630 | $4,600 | Implemented |
AM0520 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,880 | $26,180 | Implemented |
AM0520 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,240 | $1,000 | Implemented |
AM0520 # 06 Y:2007 | 06 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,340 | $10,600 | Implemented |
AM0520 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $5,170 | $4,280 | Implemented |
AM0520 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,280 | $75 | Implemented |
AM0520 # 09 Y:2007 | 09 | 2007 | INSULATE BARE EQUIPMENT | $1,910 | $750 | Implemented |
AM0520 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $430 | $480 | Implemented |
AM0520 # 11 Y:2007 | 11 | 2007 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $9,140 | $35,000 | Implemented |
TA0131 # 01 Y:2006 | 01 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $18,180 | $16 | Implemented |
TA0131 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,450 | $120 | Implemented |
TA0131 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,400 | $0 | Implemented |
TA0130 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,192 | $0 | Implemented |
TA0130 # 02 Y:2006 | 02 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $81 | $252 | Implemented |
TA0130 # 03 Y:2006 | 03 | 2006 | OPTIMIZE PLANT POWER FACTOR | $10,795 | $22,000 | Implemented |
TA0129 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,250 | $1,944 | Implemented |
TA0129 # 03 Y:2006 | 03 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $10,615 | $0 | Implemented |