IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,996

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0203 # 06 Y:1997 06 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $101 $207 Implemented
MO0203 # 07 Y:1997 07 1997 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $329 $963 Implemented
MO0203 # 08 Y:1997 08 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $993 $40 Not Implemented
MO0203 # 09 Y:1997 09 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $606 $51 Implemented
MO0203 # 10 Y:1997 10 1997 USE RE-USABLE FILTERS $4,451 $1,360 Not Implemented
MO0203 # 11 Y:1997 11 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $4,596 $5,360 Not Implemented
CO0391 # 01 Y:1997 01 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,130 $3,710 Implemented
CO0391 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $302 $403 Implemented
CO0391 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,479 $2,216 Implemented
CO0391 # 04 Y:1997 04 1997 PREHEAT COMBUSTION AIR WITH WASTE HEAT $430 $480 Not Implemented
CO0391 # 05 Y:1997 05 1997 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $27,230 $27,230 Implemented
CO0391 # 06 Y:1997 06 1997 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $3,620 $23,500 Not Implemented
BD0085 # 01 Y:1997 01 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,667 $6,050 Not Implemented
BD0085 # 02 Y:1997 02 1997 INSTALL AUTOMATIC STACK DAMPER $5,587 $1,750 Not Implemented
BD0085 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,828 $9,330 Implemented
BD0085 # 04 Y:1997 04 1997 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,772 $300 Not Implemented
BD0085 # 05 Y:1997 05 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $517 $250 Not Implemented
BD0085 # 06 Y:1997 06 1997 INSTALL OCCUPANCY SENSORS $745 $975 Not Implemented
BD0085 # 07 Y:1997 07 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $9,491 $1,000 Implemented
BD0085 # 08 Y:1997 08 1997 MINIMIZE WATER USAGE $532 $805 Not Implemented
BD0085 # 09 Y:1997 09 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,681 $1,000 Not Implemented
ND0277 # 01 Y:1997 01 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $10,296 $30,000 Implemented
ND0277 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,819 $14,790 Implemented
ND0277 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,691 $3,711 Implemented
ND0277 # 04 Y:1997 04 1997 INSTALL OCCUPANCY SENSORS $3,281 $1,200 Not Implemented