Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,230

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0060 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,900 $23,000 Not Implemented
TT0060 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,000 $39,900 Not Implemented
TT0060 # 03 Y:2011 03 2011 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $51,500 $98,000 Not Implemented
TT0060 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,700 $4,900 Not Implemented
TT0060 # 05 Y:2011 05 2011 RECOVER WASTE HEAT FROM EQUIPMENT $7,200 $4,700 Not Implemented
TT0060 # 06 Y:2011 06 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $8,700 $8,000 Not Implemented
TT0060 # 07 Y:2011 07 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $28,000 $53,000 Not Implemented
TT0060 # 08 Y:2011 08 2011 REVISE SMOKE CLEANUP FROM OPERATIONS $22,900 $20,000 Not Implemented
TT0060 # 09 Y:2011 09 2011 INSTALL TIMERS AND/OR THERMOSTATS $9,800 $200 Not Implemented
TT0060 # 10 Y:2011 10 2011 INSTALL TIMERS AND/OR THERMOSTATS $3,700 $1,600 Not Implemented
TT0060 # 11 Y:2011 11 2011 INSTALL TIMERS AND/OR THERMOSTATS $500 $600 Not Implemented
TT0060 # 12 Y:2011 12 2011 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,280 $0 Not Implemented
LE0314 # 01 Y:2011 01 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,497 $12,000 Not Implemented
LE0314 # 02 Y:2011 02 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $11,409 $580 Implemented
LE0314 # 03 Y:2011 03 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,295 $15,000 Not Implemented
LE0314 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,832 $1,420 Implemented
LE0314 # 05 Y:2011 05 2011 INSULATE BARE EQUIPMENT $4,063 $8,007 Not Implemented
LE0314 # 06 Y:2011 06 2011 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,532 $0 Implemented
LE0314 # 07 Y:2011 07 2011 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,127 $7,000 Not Implemented
LE0314 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,017 $39,066 Not Implemented
NC0421 # 01 Y:2011 01 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $28,591 $51,300 Not Implemented
NC0421 # 02 Y:2011 02 2011 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,751 $25,000 Not Implemented
NC0421 # 03 Y:2011 03 2011 REPAIR OR REPLACE STEAM TRAPS $12,484 $5,500 Implemented
NC0421 # 04 Y:2011 04 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,180 $25,000 Not Implemented
NC0421 # 05 Y:2011 05 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,844 $100 Implemented