Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,996
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0277 # 05 Y:1997 | 05 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,940 | $3,795 | Not Implemented |
ND0277 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,668 | $360 | Implemented |
ND0277 # 07 Y:1997 | 07 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $662 | $993 | Not Implemented |
ND0277 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $402 | $660 | Implemented |
ND0277 # 09 Y:1997 | 09 | 1997 | INSTALL SKYLIGHTS | $325 | $623 | Not Implemented |
ND0277 # 10 Y:1997 | 10 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $274 | $0 | Not Implemented |
ND0277 # 11 Y:1997 | 11 | 1997 | USE BUILDING MATERIALS WHICH REQUIRE LESS ENERGY TO PRODUCE | $109 | $38 | Implemented |
KU0476 # 01 Y:1997 | 01 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,340 | $0 | Implemented |
KU0476 # 02 Y:1997 | 02 | 1997 | USE RADIANT HEATER FOR SPOT HEATING | $1,540 | $5,580 | Not Implemented |
KU0476 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,360 | $5,470 | Implemented |
KU0476 # 04 Y:1997 | 04 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $230 | Implemented |
KU0476 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $780 | $1,400 | Not Implemented |
KU0476 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $490 | $780 | Not Implemented |
KU0476 # 07 Y:1997 | 07 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $370 | $810 | Not Implemented |
KU0476 # 08 Y:1997 | 08 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $180 | $270 | Implemented |
KU0476 # 09 Y:1997 | 09 | 1997 | RECYCLE CASTING SAND | $4,050 | $0 | Not Implemented |
KU0476 # 10 Y:1997 | 10 | 1997 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $3,340 | $300 | Implemented |
KU0476 # 11 Y:1997 | 11 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $7,620 | $0 | Implemented |
CO0390 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,461 | $782 | Implemented |
CO0390 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $140 | $202 | Implemented |
CO0390 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $370 | $700 | Implemented |
CO0390 # 04 Y:1997 | 04 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $310 | $730 | Implemented |
CO0390 # 05 Y:1997 | 05 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $3,220 | $3,600 | Not Implemented |
CO0390 # 06 Y:1997 | 06 | 1997 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $1,640 | $1,640 | Implemented |
CO0390 # 07 Y:1997 | 07 | 1997 | MAINTAIN/ENLARGE A STOCK OF SPARE PARTS | $7,110 | $340 | Implemented |